Uma ubheke ukwenza ngendlela oyifisayo amabhokisi okusabalalisa ekhwalithi ephezulu, cabanga ukukhethaI-I-CDADA, umkhiqizi ozinze e-China. Isungulwe ngo-2004—futhi ngezimpande ezisukela eminyakeni yawo-1980—sifaka imigqa yokukhiqiza ethuthukiswe ngokugcwele futhi sinikeza izinsiza eziphelele ze-OEM yesitobhi esisodwa. Uma unezidingo ezithile mayelana nemishini kagesi ene-voltage ephansi, ungathola lokho kanye okudingayo nathi.
A ibhokisi lokusabalalisa, owaziwa nangokuthi aibhodi lokusabalalisa, ukuhlanganiswa kwe-switchgear, noma ibhodi lebhodi, iwumhlangano ovalekile wamadivayisi okushintsha nokuvikela ugesi aklanyelwe ukuthola amandla kagesi avela emthonjeni futhi awasabalalise kumasekhethi amaningi. Isebenza ngaphansiI-I-IEC 61439 (izinga lamazwe ngamazwe lama-switchgear aphansi kanye namagiya okulawula), amabhokisi okusabalalisa asebenza njengesizinda esibalulekile sokuphathwa kwamandla kagesi ezindaweni zokuhlala, ezohwebo, nezimboni.
Amabhokisi okusabalalisa asukela kokuncaneamayunithi abathengi basekhaya (amamojula angu-16-24) kuya kumakhuluizikhungo zokusabalalisa amandla ezimbonini (kufika ku-6300A). Bahlanganisa ama-circuit breaker, amadivaysi amanje asele,abathintwayo, amabhasi, nezinto zokuqapha ngaphakathi kwendawo evalekile, eqinisekisa ukusatshalaliswa kwamandla okuphephile, okuthembekile, nokuhlelekile.
IUchungechunge olujwayelekile lwe-I-IEC 61439 iguqule imboni ngokufaka esikhundleni sochungechunge oludala lwe-IEC 60439, yethula izidingo zokuqinisekisa umklamo ocacile, izimiso ezivamile zokuqinisekisa, kanye nezinyathelo zokuphepha ezithuthukisiwe zokuvikela kokubili abantu nempahla.
|
Ukwahlukanisa |
Uhlobo |
Ububanzi Bamanje |
Izimpawu Ezisemqoka |
|
NgokweZinga (IEC 61439) |
I-IEC 61439-3 (DBO) |
≤250A |
Amabhodi okusabalalisa asetshenziswa abantu abajwayelekile, abasekhaya/bezentengiselwano, amasekethe aphumayo ≤125A |
|
I-IEC 61439-2 (PSC) |
≤6300A |
Imihlangano ye-switchgear yamandla, izimboni, ukusebenza kochwepheshe kuphela |
|
|
I-IEC 61439-4 (ACS) |
≤1000A |
Imihlangano yezindawo zokwakha, eyesikhashana, ephathekayo/ehambayo |
|
|
I-IEC 61439-5 |
≤2500A |
Amanethiwekhi okusabalalisa umphakathi, amakhabethe okusabalalisa amakhebula |
|
|
I-IEC 61439-7 |
Iyahlukahluka |
Izinhlelo zokusebenza eziqondile: ama-marinas, ukushaja kwe-EV, izikwele zemakethe |
|
|
Ngokukhwela |
Ifakwe odongeni |
≤630A |
Ukukhweza okungaphezulu noma okushaywayo, IP30-IP65, indawo yokuhlala/yokuhweba |
|
Ukuma phansi |
≤6300A |
Okuzimele, ukwakhiwa kwe-modular, izikhungo zezimboni/zamandla |
|
|
Ifakwe ngepali |
≤400A |
Ukusabalalisa ngaphandle, ukukhanya komphakathi, ukufakwa kukagesi ezindaweni zasemakhaya |
|
|
Ngokwakha |
Insimbi ebiyelwe |
Zonke izilinganiso |
Insimbi/i-Aluminium, IP30-IP65, isivikelo sikagesi |
|
Ama-insulated ezivalekile |
≤250A |
I-Thermoplastic (ABS, PC), IP40-IP65, ukumelana nokugqwala |
|
|
Amasistimu we-modular |
≤630A |
Ukukhweza ujantshi we-DIN, i-modularity engu-17.5mm, ukucushwa okuguquguqukayo |
|
|
Ngesicelo |
Indawo yokuhlala |
≤250A |
Isigaba esisodwa/isigaba sesithathu, ukuhlanganiswa kwe-MCB/RCD, amayunithi abathengi |
|
Ezohwebo |
≤630A |
Ukusatshalaliswa kwezigaba ezintathu, amabhodi okusabalalisa okuncane, ukulinganisa |
|
|
Izimboni |
≤6300A |
Izikhungo zokulawula izimoto, ukusatshalaliswa kwamandla, ukulawulwa kwenqubo |
|
|
Ingqalasizinda |
≤2500A |
Izinsiza, izikhungo zedatha, ukunakekelwa kwezempilo, ezokuthutha |
Ubukhulu obujwayelekile (Amasistimu ajwayelekile):
Ububanzi370mm, 450mm, 620mm, 700mm, 900mm, 1000mm
UbudeUbukhulu: 500 mm 2010 mm
Ukujula: 267mm kuya ku-800mm (inwebeke ibe ngu-1000mm)
Umthamo wemojuli:10, 24, 36 amamojula (17.5mm pitch)
|
Umsebenzi |
Incazelo |
Ukuqaliswa Kwezobuchwepheshe |
|
Ukwamukela Amandla |
Yamukela amandla angenayo avela ku-transformer, i-generator, noma ukusatshalaliswa komfula |
I-circuit breaker eyinhloko engenayo (ICB), isinqamuli-swishi, noma i-fuse-switch |
|
Ukusabalalisa Amandla |
Ihlukanisa amandla angenayo kumasekethe amagatsha amaningi |
Amabhasi (ithusi/i-aluminium), amatheminali okusabalalisa, ama-circuit breakers |
|
Ukuvikelwa Kwesekethe |
Ivikela ekulayisheni ngokweqile, amasekhethi amafushane, namaphutha omhlaba |
Ama-MCB, ama-MCCB, ama-RCD, ama-RCBO, ama-fusegear |
|
Ukuzihlukanisa |
Inikeza ukunqanyulwa okuphephile kokulungisa |
Iswishi eyinhloko, izinqamuli zokushintsha ezinoxhumana nabo ababonakalayo |
|
Ukuqapha nokulawula |
Ilinganisa, iqaphe, futhi ilawule amapharamitha kagesi |
Amamitha wamandla, abahlaziyi bekhwalithi yamandla, ukuqapha okukude, ama-smart breaker |
|
Ikhwalithi Yamandla |
Ukuvikelwa kwe-surge, ukuhlunga kwe-harmonic, ukulungiswa kwesici samandla |
Ama-SPD, izihlungi ezisebenzayo, amabhange e-capacitor |
Amabhasi akha umgogodla wamabhokisi okusabalalisa, aqhuba imisinga ephezulu phakathi kwamasekethe angenayo naphumayo:
|
Ipharamitha |
Ukucaciswa |
Amazinga Abalulekile |
|
I-Busbar Material |
Ithusi elidonsa kanzima (C11000) noma ingxubevange ye-aluminium (6101-T6) |
I-ASTM B187, IEC 60428 |
|
Ukuminyana Kwamanje |
1.0-1.6 A/mm² (ithusi), 0.8-1.2 A/mm² (i-aluminium) |
Ukunyuka kwezinga lokushisa kukhawulelwe ku-65K (engenalutho), 80K (okupuletiwe) |
|
I-Short-Circuit Withstand |
10kA-100kA kowoku-1 (Icw) |
I-IEC 61439-1, ukuqinisekiswa kokucindezeleka okunamandla nokushisa |
|
Ukwelashwa Okungaphezulu |
I-tin Plating (8-12μm) noma isiliva yokucwenga (3-5μm) |
Ukumelana nokugqwala, ukwethembeka kokuxhumana |
|
Sekela ama-Insulators |
I-DMC (Inhlanganisela Yokubumba Inhlama) noma i-SMC (Inhlanganisela Yokubumba Ishidi) |
I-IEC 60168, inkomba yokulandelela> 600V |
|
Ukucushwa kwe-Busbar |
3-isigaba + N + PE, noma 3-isigaba + N (ezodwa) |
Ukulandelana kwesigaba L1-L2-L3, kwesokudla kwesokunxele noma kwesokudla |
Isibonelo sosayizi webha yebhasi:
2000kVA transformer, 400V, 3-isigaba
Ukulayisha okugcwele kwamanje: 2887A
Ukukhetha ibha yebhasi: 2× T2 imigoqo yethusi, 120mm × 10mm ngesigaba ngasinye (2400mm²)
Ukuminyana kwamanje: 1.2 A/mm²
Ukumelana ne-short-circuit: 50kA/1s aqinisekiswe ngokuhlolwa noma ngokubala nge-IEC/TR 60890 ngayinye
|
Isicelo |
Uhlobo Lwesistimu |
Imininingwane Ejwayelekile |
Izidingo Eziyinhloko |
|
Izakhiwo Zokuhlala |
Iyunithi yabathengi, ukusatshalaliswa kwefulethi |
≤250A, IP40, okufakwe odongeni, amamojula angu-12-24, MCB+RCD |
Ukuphepha kwabantu abajwayelekile, ukungasebenzi kahle, ukulebula okucacile |
|
Amahhovisi Ezohwebo |
Ibhodi lokusabalalisa kancane, ukusatshalaliswa phansi |
≤400A, IP30-IP54, udonga/iphansi, amamojula angama-36-72, ukulinganisa |
Ukuguquguquka kwezinguquko zomqashi, i-sub-metering, ukunwetshwa okuzayo |
|
Izitolo Zokuthenga |
Ukusabalalisa abaqashi, ukusatshalaliswa okukhulu |
≤630A, IP54, ukuma phansi, i-modular, ukuqapha okuhlakaniphile |
Ukutholakala okuphezulu, ukuphathwa komthwalo, ukuqapha okuphakathi nendawo |
|
Izikhungo Zedatha |
Iyunithi yokusabalalisa amandla (i-PDU), ukucisha ibhasi |
≤1600A, IP20, ukuma phansi, 3N+PE, ukungafuneki |
99.999% ukutholakala, ukushintshwa okushisayo, ukuqapha okukude |
|
Izimboni zezimboni |
Isikhungo sokulawula izimoto (MCC), isikhungo sokusabalalisa amandla |
≤6300A, IP42-IP54, ukuma phansi, ukuhlukaniswa kweFomu 4 |
I-high short-circuit ukumelana, ukuvikelwa kwemoto, ukuhlanganiswa kwenqubo |
|
Izinsiza Zezempilo |
Ukusabalalisa amandla abalulekile, amandla angawodwa |
≤800A, IP30, i-medical-grade, ukuhambisana kwesistimu ye-IT |
Ukuphepha kwesiguli, ukuqhubeka kokunikezwa, ukuvuza kokuqapha kwamanje |
|
Amandla Avuselelekayo |
Ibhokisi lokuhlanganisa i-Solar, ukusatshalaliswa kwesitoreji sebhethri |
≤1500V DC, IP65, ngaphandle, ukuqapha kwentambo |
Ukuvikelwa kwephutha kwe-DC arc, ukuvala shaqa ngokushesha, ukuqina kwemvelo |
|
Izindawo Zokwakha |
Ukusatshalaliswa kwamandla esikhashana, amakhabethe esayithi |
≤400A, IP44-IP65, ukwakhiwa okuphathekayo, okuqinile |
Ukuhamba, ukumelana nesimo sezulu, ukuphepha ukuze kusetshenziswe isikhashana |
I-Raw Material I-IQC → Ukwenziwa Kwensimbi Yeshidi → Ukwelashwa Okungaphezulu → Ukucutshungulwa Kwebhasi → Ukuhlanganiswa Kwengxenye → Izintambo & Ukuhlanganiswa → Ukuhlola Nokuqinisekisa → I-QC Yokugcina → Ukupakisha Nokulethwa
|
Isiteji |
Imininingwane Yenqubo |
Amaphuzu Okulawula Ikhwalithi |
|
Sheet Metal Fabrication |
Insimbi egoqiwe ebandayo (CRCA) noma ishidi le-aluminium, ukusika i-laser, ukubhoboza kwe-CNC, ukugoba, ukushisela |
Ukubekezelela i-Dimensional ±0.5mm, imiphetho engena-burr, ukungena kwe-weld, flatness <1mm/m |
|
Ukwelashwa Okungaphezulu |
Ukukhipha amafutha, ukuphosphating, i-electrostatic powder coating (epoxy-polyester), ukwelapha (180-200°C/20min) |
Ukuqina kwe-coating 60-80μm, ukuhlolwa kwe-adhesion cross-cut 0-1, isifutho sikasawoti 500-1000h |
|
I-Busbar Processing |
Ukusika, ukubhoboza, ukugoba, uthayela/ucwecwe lwesiliva, umkhono wokuvala umkhono |
I-Conductivity ≥100% IACS (ithusi), ukujiya kwe-plating 8-12μm, awekho ama-burrs, ukuzungezisa komphetho |
|
Ukukhweza Ingxenye |
Ukufakwa kukajantshi we-DIN, ukukhwezwa kwe-breaker circuit, ukuxhumeka kwebha yebhasi, ukuqiniswa okulawulwa yitorque |
I-torque ngomkhiqizi ngamunye (1.5-5.0Nm), ukuqondanisa, imvume/ukuqinisekisa kwekhasi elidala |
|
Izintambo zangaphakathi |
Izintambo zethusi (H05RR-F, H07RN-F), ukunqanyulwa kwe-ferrule, ukufaka ikhodi kombala (L1-brown, L2-black, L3-grey, N-blue, PE-green/yellow) |
Ukuhlolwa kokuqhubeka, ukumelana nokufakwa kwe-insulation > 1MΩ, izigaba ezifanele |
|
Ukuqinisekiswa Komhlangano |
Ukusebenza ngomshini, ukukhiya kwezicabha, ukuvalwa, ukulebula, imibhalo |
Ukuhlola ukusebenza okungu-100%, ukuqinisekiswa kwe-IP, ukuhambisana ne-IEC 61439-1 |
|
Ukuhlola Nokuqinisekisa |
Ukuhlolwa kwe-Dielectric (2kV/1min), ukumelana nokufakwa kwe-insulation, ukuqhubeka, i-polarity, ukulandelana kwesigaba |
Ukuqinisekiswa okujwayelekile nge-IEC 61439-1, ukukhiqizwa kombiko wokuhlola |
|
Ukuhlola Okokugcina |
Ukuhlolwa okubonakalayo, isheke le-dimensional, ukubuyekezwa kwemibhalo, ukuqinisekiswa kokumaka |
Isimemezelo sokuvumelana, ifayela lobuchwepheshe, imanuwali yokufaka |
|
Isakhi |
Ukucaciswa Kwempahla |
Amazinga Womphakeli |
Izakhiwo Eziyinhloko |
|
Umzimba Obiyelwe |
I-SPCC yensimbi egoqwe ebandayo (1.0-2.0mm) noma i-aluminium 5052-H32 (1.5-3.0mm) |
I-JIS G 3141, ASTM B209 |
Amandla okukhiqiza ≥180MPa, amandla kazibuthe (insimbi), ukumelana nokugqwala (Al) |
|
I-Powder Coating |
I-Epoxy-polyester hybrid, i-RAL 7035 (impunga ekhanyayo) noma i-RAL 7032 (itshe elimpunga) |
ISO 12944, Qualicoat |
Ukuqina 60-80μm, isicwebezelisi 60-80%, ukumelana nomthelela >50cm·kg |
|
Amabhasi |
I-Electrolytic copper T2 (Cu-ETP, ≥99.9%) noma i-aluminium 6101-T6 |
I-ASTM B187, IEC 60428 |
I-Conductivity ≥100% IACS (Cu), ≥55% IACS (Al), ubulukhuni HV 80-120 |
|
I-Busbar isekela |
I-DMC (Inhlanganisela Yokubumba Inhlama) noma i-SMC (Inhlanganisela Yokubumba Ishidi) |
I-IEC 60168, UL 94 V-0 |
Inkomba yokulandelela >600V, ukumelana nokushisa ku-180°C, amandla aguquguqukayo >150MPa |
|
Isitimela se-DIN |
Insimbi (i-zinc-plated) noma i-aluminium (i-anodized), TH35 (35mm × 7.5mm) |
I-IEC 60715, EN 50022 |
Ukuqina <0.5mm/m, umthamo wokulayisha>100N, ukumelana nokugqwala |
|
Izigxivizo zeminyango |
Irabha ye-EPDM noma i-polyurethane foam, iphrofayili ye-gasket |
I-ASTM D2000, UL 50 |
Ibanga lokushisa -40°C ukuya +120°C, ukucindezela isethi <25%, IP65 sealing |
|
Amahinge & Locks |
Zinc alloy (ZDC) noma insimbi engagqwali 304, chrome-plated |
I-ASTM B86, ISO 9227 |
Isifutho sikasawoti esingu-240-500h, impilo yomjikelezo > ukusebenza kwe-10,000, ukumelana nokuphazamiseka |
|
Izindlala zekhebula |
I-Polyamide (PA66) noma i-nickel-plated brass, IP68 |
I-IEC 62444, UL 514B |
Izinga lokushisa -40°C ukuya ku-+100°C, ukukhululeka kobunzima, inketho yokuvikela i-EMC |
|
I-Insulation Materials |
I-PET (Mylar), i-PVC, noma i-nomex ye-insulation yebhasi |
I-IEC 60216, UL 94 V-0 |
Amandla e-Dielectric >15kV/mm, inkomba yezinga lokushisa >130°C |
|
Okujwayelekile |
Ububanzi |
Izidingo Ezisebenzayo |
|
I-IEC 61439-1:2020 |
Imithetho evamile yama-switchgear ane-voltage ephansi kanye nemishini yokulawula |
Izinga lesisekelo, ukuqinisekiswa kwedizayini, ukuqinisekiswa okujwayelekile, ukukhuphuka kwezinga lokushisa, ukumelana nesifunda esifushane |
|
I-IEC 61439-3:2024 |
Amabhodi okusabalalisa asetshenziswa abantu abajwayelekile (DBO) |
Okwasekhaya/kwezohwebo, ≤250A, ≤300V emhlabeni, ukuphepha kwabangewona ochwepheshe |
|
I-IEC 61439-2:2011 |
Imishini yokushintsha amandla kanye nemishini yokulawula |
Imboni, ukusetshenziswa kochwepheshe kuphela, kufika ku-6300A |
|
I-IEC 61439-4:2023 |
Imihlangano yezindawo zokwakha (ACS) |
Ukufakwa kwesikhashana, ukwakhiwa okuphathekayo, okuqinile |
|
I-IEC 61439-6:2012 |
Amasistimu we-Busbar trunking (imigwaqo yamabhasi) |
Ukusabalalisa amandla ngamabhasi, amapayipi amakhulu akhuphukayo, amayunithi okukhipha amanzi |
|
I-IEC 61439-7:2014 |
Izinhlelo zokusebenza ezithize (ama-marina, ukushaja kwe-EV, njll.) |
Izindawo ezikhethekile, izidingo zokuphepha ezengeziwe |
|
I-IEC 62208:2011 |
Izivalo ezingenalutho zokuhlanganisa ama-switchgear ane-voltage ephansi |
Ukusebenza kwendawo ebiyelwe, ukuvikelwa kwemvelo, amandla emishini |
|
I-IEC/TR 60890:2014 |
Ukuqinisekiswa kokwenyuka kwezinga lokushisa ngesibalo |
Okunye ukuhlola, ukumodela okushisayo |
|
I-IEC/TR 61439-0:2013 |
Umhlahlandlela wokucacisa imihlangano |
Ukucaciswa komsebenzisi, imingcele yesixhumi esibonakalayo |
|
Uhlobo lokuqinisekisa |
Ukuhlola/Ukubala |
Imibandela Yokwamukela |
|
Ukuqinisekiswa Kwedizayini (Ukuhlolwa Kohlobo) |
Imikhawulo yokwenyuka kwezinga lokushisa |
Amatheminali ≤80K (agcwele), ≤65K (angenalutho); Indawo ebiyelwe ≤40K; Amabhasi ngempahla ngayinye |
|
I-short-circuit ukumelana namandla |
I-Icw ye-1s, i-Ipk peak current, akukho deformation, ayikho ingozi, isebenza ngemva kokuhlolwa |
|
|
Izici ze-Dielectric |
2kV-3.5kV/1min amandla imvamisa, akukho ukuhlukana, akukho flashover |
|
|
Ukucaciswa kanye namabanga e-creepage |
Ngokwedigri yokungcola, umfutho olinganiselwe umelana ne-voltage |
|
|
Ukusebenza komshini |
Ukusebenza okungu-200-1000, akukho ukugqokwa ngokweqile, izidingo zamandla |
|
|
Izinga lokuvikela (IP) |
Ukuqinisekiswa kwekhodi ye-IP (uthuli, amanzi), i-IEC 60529 |
|
|
Ukumelana nokugqwala |
Isifutho sikasawoti, umswakama, akukho ukuwohloka okuthinta ukuphepha |
|
|
Ukuqinisekiswa Komjikelezo (Yonke Iyunithi) |
Ukulunga kwezintambo, ukusebenza kokusebenza |
Ukuqhubeka, i-polarity, izigaba, umsebenzi wemishini |
|
Ukuhlolwa kwe-Dielectric |
1kV-2kV/1s noma 2U+1000V, akukho ukwehlukana |
|
|
Ukumelana ne-insulation |
≥1000Ω/V ku-500V DC |
|
|
Izinyathelo zokuzivikela, ukuqhubeka kukagesi |
≤0.05Ω phakathi kwezingxenye eziveziwe ze-conductive kanye netheminali ye-PE |
|
Okubalulekile |
Izinto Zokuhlola |
Uhlelo lwesampula |
Izisetshenziswa |
|
Amashidi ensimbi |
Ubukhulu, amandla esivuno, izinga eliphezulu, ukunamathela kokunamathela |
Iqoqo ngalinye, ukuhlolwa kwe-COA + |
Umhloli we-tensile, igeji yokuqina kokuqina, umhloli wokugoba |
|
Aluminium sheets |
I-alloy grade, ukujiya, ikhwalithi ye-anodizing |
Ngeqoqo ngalinye |
I-Spectrometer, i-micrometer, umhloli wokuqina we-anodizing |
|
Amabhasi e-Copper |
Ubumsulwa, conductivity, ubulukhuni, ukubekezelelana dimensional |
Ngeqoqo ngalinye |
Imitha ye-conductivity, isihloli sokuqina, i-CMM |
|
I-Powder enamathela |
Umbala ofanayo, isicwebezelisi, idigri yokwelapha, ukujiya |
Ngeqoqo ngalinye |
Imitha ecwebezelayo, imitha yokwelapha, igeji yokujiya, i-spectrophotometer yombala |
|
Izingxenye zepulasitiki |
Ukuvutha (UL 94), inkomba yokulandelela, ukuzinza kobukhulu |
Ngeqoqo ngalinye |
Izisetshenziswa zokuhlola ze-UL 94, ukuhlolwa kokulandela umkhondo, isihloli sokuhlanekezela ukushisa |
|
Isiteshi |
Lawula Amapharamitha |
Imvamisa |
Indlela |
|
Ukusika / ukubhoboza nge-laser |
Ukunemba kobukhulu ±0.2mm, ikhwalithi yomphetho, ubude be-burr |
Njalo ngemizuzu engama-30 |
I-CMM, ukuhlolwa okubonakalayo, i-micrometer |
|
Ukugoba |
Ukunemba kwe-engeli ±0.5°, irediyasi yokugoba, ukuqhekeka kwendawo |
Konke ukusetha + isampula |
I-engeli gauge, i-radius gauge, ukuhlolwa okubonakalayo |
|
Ukushisela |
Ukungena, ukubukeka kobuhlalu, ukulawula ukuhlanekezela |
Wonke ama-weld batch |
Ukuhlola okubonakalayo, ukungena kodayi, i-X-ray (okubalulekile) |
|
I-Powder enamathela |
Ukujiya kwefilimu 60-80μm, uhlelo lokwelapha, ukungaguquguquki kombala |
Wonke amaqoqo |
Igeji yokuqina, imitha yokwelapha, ukuqhathanisa nombala |
|
Ukucubungula ibha yebhasi |
Ubude bokusika, iphethini yembobo, ukujiya kwe-plating, ukujikeleza komphetho |
Zonke izingcezu |
CMM, XRF Plating ukujiya, ukuhlolwa okubukwayo |
|
Umhlangano |
I-torque yokufaka ingxenye, ukuqondanisa, amabanga okukhipha |
Wonke amayunithi |
I-torque wrench, amabhlogo wegeji, ukuhlolwa okubonakalayo |
|
Into yokuhlola |
Okujwayelekile |
Usayizi Wesampula |
|
Ukuqinisekiswa kwe-Dimensional |
Ubukhulu bebonke, ukuqondanisa kweminyango, izimbobo ezifakwayo |
100% |
|
Ukuqinisekiswa kwesilinganiso se-IP |
Ubuqotho be-Seal, ukucindezelwa kwe-gasket, ukuvalwa komnyango |
I-AQL 1.0 (isampula) |
|
Ukuhlolwa kwe-Dielectric ukumelana |
2kV AC/1min (amasekhethi amakhulu), 1kV AC/1min (insiza) |
100% |
|
Ukumelana ne-insulation |
≥1MΩ @ 500V DC |
100% |
|
Ukuqhubeka kwamasekhethi okuvikela |
≤0.05Ω phakathi kwamaphoyinti e-PE |
100% |
|
I-polarity nokuqinisekiswa kwezigaba |
Lungiselela kuwo wonke amatheminali |
100% |
|
Ukusebenza komshini |
Umnyango, izingidi, amahinge, izingxenye ezikhiphekayo |
100% |
|
Ukuhlola okubonakalayo |
Ukukhubazeka kokumboza, ukulebula, ukuhlanzeka |
100% |
|
Ukubuyekezwa kwamadokhumenti |
Imidwebo yezintambo, imibiko yokuhlolwa, isimemezelo sokuvumelana |
100% |
|
Ubuqotho bokupakisha |
Ukuvikelwa ngesikhathi sokuthutha, imiyalelo yokuphatha |
Ngamunye |
|
Isigaba Sezisetshenziswa |
Ukucaciswa komshini |
Umsebenzi |
Amandla |
|
Ishidi Metal Processing |
I-CNC laser cutting |
Ukusika okunembayo, amaphrofayili ayinkimbinkimbi, imiphetho engena-burr |
amathani ayi-10/ngosuku |
|
CNC isibhakela |
Amaphethini wemigodi, ama-louvers, embossing |
5,000 amaphaneli/ngosuku |
|
|
I-CNC press brake |
Ukugoba okunembayo, amajiyometri ayinkimbinkimbi |
2,000 ezivalekile/ngosuku |
|
|
Ukwelashwa Okungaphezulu |
I-automated powder coating line |
Ukwelashwa kwangaphambili, ukufaka impushana, ukwelapha |
5,000 m²/ngosuku |
|
I-Busbar Processing |
Ibha yebhasi ye-CNC yokubhoboza/umshini wokugoba |
Ukusika, ukubhoboza, ukugoba, ukucwenga |
2,000 amasethi ebhasi/ngosuku |
|
Imigqa Yomhlangano |
Iziteshi zomhlangano ezijwayelekile, ukuvikelwa kwe-ESD, ukuqapha kwetorque |
Ukukhweza ingxenye, izintambo, ukuhlola |
1,000 amabhokisi okusabalalisa/ngosuku |
|
Izisetshenziswa zokuhlola |
Ibhentshi lokuhlola elizenzakalelayo (i-dielectric, insulation, ukuqhubeka) |
Ukuqinisekiswa okujwayelekile ngokwe-I-IEC 61439 |
500 amayunithi / ngosuku |
|
Ukusethwa kokuhlolwa kwezinga lokushisa (umjovo wamanje ungafika ku-6300A) |
Ukuqinisekiswa kwedizayini, ukuhlolwa kohlobo |
10 ukusetha/ngenyanga |
|
Isigaba somkhiqizo |
Amandla Wanyanga zonke |
Isikhathi Esijwayelekile Sokuhola |
Amandla Woku-oda Okuphuthumayo |
|
I-DBO yokuhlala (≤250A, ifakwe odongeni) |
50,000 amayunithi |
4-5 amaviki |
3 izinsuku |
|
Ukusabalalisa kwezohwebo (≤630A, phansi/udonga) |
20,000 amayunithi |
4-5 amaviki |
5 izinsuku |
|
Izikhungo zamandla ezimboni (≤2500A, ukuma phansi) |
5,000 amayunithi |
4-5 amaviki |
izinsuku ezingu-7 |
|
Izixazululo ezenziwe ngokwezifiso (≤6300A) |
Isisekelo sephrojekthi |
4-8 amasonto |
2-3 amasonto |
|
Amasistimu webhasi ye-modular |
10,000 amamitha |
4-5 amaviki |
5 izinsuku |
|
Umnyango |
Abasebenzi |
Uchwepheshe |
Izibopho |
|
Ubunjiniyela be-R&D |
5 onjiniyela |
Ukuhambisana kwe-IEC 61439, imodeli eshisayo, ukubala kwesifunda esifushane, isayensi yezinto ezibonakalayo |
Ukuthuthukiswa komkhiqizo omusha, ukwenziwa ngcono kwedizayini, iphothifoliyo yelungelo lobunikazi (amalungelo obunikazi angama-40+) |
|
Ubunjiniyela Bezinqubo |
25 onjiniyela |
Ukwenziwa kwensimbi yeshidi, ukwelashwa kwendawo, ukucubungula ibha yebhasi, ukukhiqizwa okunciphile |
Ukwenziwa ngcono kokukhiqiza, okuzenzakalelayo, ukuthuthukiswa kwesivuno (>98%), ukuncishiswa kwezindleko |
|
Ukuhlola Nokuqinisekisa |
20 onjiniyela |
Ukuqinisekiswa kwe-IEC 61439, ukuhlolwa kokukhuphuka kwezinga lokushisa, ukuhlolwa kwesifunda esifushane, i-EMC |
Ukudidiyelwa kokuhlolwa kohlobo, ukuqinisekiswa okujwayelekile, ukuhlaziya ukwehluleka, ukunikezwa isitifiketi |
|
Ubunjiniyela bohlelo lokusebenza |
15 onjiniyela |
Idizayini yesistimu yamandla, ukuxhumana okukhethiwe, ukugadwa kokufakwa, ukugunyazwa |
Ukwesekwa kobuchwepheshe bekhasimende, ukuklanywa kwesikimu, ukugadwa kwesayithi, ukuqeqeshwa |
|
Ukuqinisekisa ikhwalithi |
35 ochwepheshe |
ISO 9001, ISO 14001, ukulawulwa kwenqubo yezibalo, ilabhorethri ye-metrology |
Ukucwaningwa kwabahlinzeki, ukuhlolwa kwenqubo, isenzo sokulungisa, ukuphathwa kokulinganisa |
Indawo yethu yokukhiqiza imeleIminyaka engu-25 yobungcweti emibuthanweni ye-switchgear ene-voltage ephansi, iletha amabhokisi okusabalalisa aweqa amazinga omhlaba ngokusebenzisa:
Ubuchwepheshe be-I-IEC 61439: Amandla okuqinisekisa umklamo ophelele ahlanganisa ukubala kokukhuphuka kwezinga lokushisa nge-IEC/TR 60890 ngayinye kanye nokuqinisekiswa kokumelana nesekethe emfishane ngokweSijobelelo P se-IEC 61439-1 ngasinye
Ukuhlanganiswa okuqondile: Ukwakhiwa kweshidi lensimbi yasendlini (ukusika i-laser, ukubhoboza, ukugoba), ukwelashwa kwendawo (i-automated powder coating), kanye nokucutshungulwa kwe-busbar kuqinisekisa ukulawulwa kwekhwalithi okuphelele
Ingqalasizinda yokuhlola:U-$5M+ utshalwe kumishini yokuhlola uhlobo oluhlanganisa ukusetha kokuhlolwa kokukhuphuka kwezinga lokushisa (umjovo wamanje ongu-6300A), izindawo zokuhlola isifunda esifushane, namagumbi emvelo.
Ukuvumelana nezimo Modular:Imiklamo yeplathifomu esezingeni evumela ukwenziwa ngokwezifiso ngokushesha ngenkathi igcina ukuthobela kwe-IEC 61439 nokusebenza kahle kwezindleko
Ubuchwepheshe bokufaka isicelo:Izixazululo ezikhethekile zezikhungo zedatha (ukuhlukaniswa kweFomu 4), ukunakekelwa kwezempilo (amasistimu we-IT), amandla avuselelekayo (ukusabalalisa kwe-DC), kanye nezindawo ezinokhahlo (IP65, ezishisayo)