Ingabe udinga ama-Earth Leakage Circuit Breaker asezingeni eliphezulu futhi aqinile?I-I-CDADAinikeza izixazululo ezibanzi zokwenza ngokwezifiso ze-OEM. Njengomkhiqizi onokwethenjelwa onemboni yethu, sinikeza iwaranti yeminyaka emi-3 emikhiqizweni yethu.
AnI-I-Earth Leakage Circuit Breaker (CBR), obeye aziwe njengoI-Earth Leakage Circuit Breaker ene-Integral Overcurrent Protection (CBR) nge-IEC 60947-2 Annex B ngayinye, iyithuluzi eliyinkimbinkimbi lokuvikela i-low-voltage elihlanganisaukuvikelwa kwamanje (ukuvuza komhlaba) okusele ngeukulayisha ngokweqile kanye nokuvikela isifunda esifushane kuyunithi yekesi elilodwa elibunjiwe. Isebenza ngama-voltage akalwe afika phezulu415V AC (50/60Hz) ngezilinganiso zamanje ezivela16A kuya ku-800A, ama-CBR asebenza njengamathuluzi okuvikela aphelele ezimbonini, ezentengiselwano, nezisetshenziswa zengqalasizinda ezibalulekile .
Ngokungafani nokuzimelaIzinqamuli Zomjikelezo Zamanje Ezisele (RCCBs)ehlinzeka ngokuvikelwa kokuvuza komhlaba kuphela, ama-CBR ahlanganisa:
Ukuvikelwa kwe-thermal-magnetic noma i-electronic overcurrent (Amajika e-L-S-I)
Ukutholwa kwamanje okuyinsalela (Ukuzwela kwe-10mA kuya ku-1000mA)
Amandla okuphuka kwesiyingi esifushane kuze kufike ku-85kA
Lokhu kuhlanganiswa kuqeda isidingo sezinhlanganisela ezihlukene ze-MCB/RCCB, kunciphisa indawo yokufaka nokuthuthukisa ukwethembeka kokuxhumana .
|
Ukwahlukanisa |
Uhlobo |
Ububanzi Bamanje |
Izimpawu Ezisemqoka |
|
Uhlobo Lwamanje Olusele |
Thayipha i-AC |
16A – 800A |
Ithola imisinga eyinsalela ye-AC ye-sinusoidal kuphela, izinhlelo zokusebenza zenhloso evamile |
|
Uhlobo A |
16A – 800A |
Ithola i-AC + pulsating DC (i-AC elungisiwe), imithwalo yesimanje kagesi |
|
|
Ukuzwela (IΔn) |
Ukuzwela Okuphezulu |
10mA – 30mA |
Ukuvikelwa kwabasebenzi, izindawo zokwelashwa, izindawo ezimanzi |
|
Ukuzwela Okumaphakathi |
100mA – 300mA |
Ukuvikelwa komlilo, izimboni ezijwayelekile |
|
|
Ukuzwela Okuphansi |
500mA – 1000mA |
Ukuvimbela umlilo ekufakweni kokuvuza okuphezulu, ukuvikela okukhethiwe |
|
|
Isikhathi Ukubambezeleka |
Ngokushesha |
Zonke izilinganiso |
Inhloso evamile, <40ms ku-5×IΔn |
|
Okukhethiwe (S-Type) |
100mA – 1000mA |
Ukuhamba ukubambezeleka (130-500ms ku-1×IΔn), ukucwasa okukhuphuka nomfula |
|
|
I-Pole Configuration |
4-Isigxobo |
16A – 800A |
Izigaba ezintathu + ukungathathi hlangothi, ukuvikeleka okungathathi hlangothi okulungiswayo (50-100%) |
|
Ukukhweza |
Kulungisiwe |
16A – 800A |
Ukuxhumeka okuqondile kwebha yebhasi, kuyabiza |
Amabanga Wokuphulwa Kwekhono:
Okujwayelekile (N): 25kA – 36kA (Amanethiwekhi okusabalalisa)
Phezulu (S)Amandla: 50kA - 70kA (amapayipi amakhulu ezimboni)
I-I-Ultra-High (H)Amandla: 85kA (Ingqalasizinda yamandla)
|
Umsebenzi |
Isimiso Sokuthola |
Imingcele Yezobuchwepheshe |
|
I-Overload Protection (L) |
I-Bimetallic thermal expansion noma inzwa ye-RMS ye-elekthronikhi |
0.8 – 1.0 × Esimeni, ijika lesikhathi eliphambene, ±10% ukunemba |
|
Ukubambezeleka Komjikelezo Omfushane (S) |
Isikhathi sikagesi noma ukubambezeleka kazibuthe |
2-10 × Ngaphakathi, 0.1s – 0.5s ukubambezeleka, ukukhetha ukukhetha |
|
Uhambo Olusheshayo (I) |
I-solenoid ye-Magnetic noma i-electronic esheshayo |
5-20 × In, <20ms ukusebenza, umkhawulo wamanje |
|
Ukuvuza komhlaba (G/Δ) |
I-I-Core Balance Current Transformer (CBCT) |
10mA – 1000mA IΔn, ±10% ukunemba kokuzwela |
|
I-Ground Fault (GF) |
Inzwa yamanje yesamba seVector |
20-100% we-In, 0.1s-1.0s ukubambezeleka, indlela yebhalansi eyisisekelo |
|
Ukuziqapha |
Ukuhlolwa kobuqotho besekethe yangaphakathi |
I-CBCT eqhubekayo kanye nokuqapha ikhoyili yohambo, ukuphuma kwe-alamu yephutha |
II-I-Core Balance Current Transformer (CBCT) nomaI-I-Toroidal Transformer yakha inhliziyo yokuvikela ukuvuza komhlaba:
Ukusebenza Okuvamile: Wonke ama-conductor aphilayo (isigaba + angathathi hlangothi) adlula kumongo we-toroidal. Ama-currents alinganiselayo akhiqiza izingxenyekazi kazibuthe eziphikisanayo ezikhansela ku-zero net flux—ayikho imanje yesibili eyenzelwe .
Isimo Sephutha: Uma ukuvuza kwamanje kugeleza emhlabeni (ngokwehluleka kokufakwa ngaphakathi noma ukuthintana nomuntu), ukungalingani kwamanje kudala i-flux kazibuthe eyinsalela kumongo we-toroidal. Lokhu kuguquguquka kubangela i-voltage kumajika esibili, inika amandla ukudluliselwa okuzwelayo noma isekethe yohambo lwe-elekthronikhi.
Izimpawu Zohambo nge-IEC 61008/61009:
1 × IΔn: Uhambo ≤ 300ms (ngokuphazima kweso), ≤ 500ms (uhlobo olukhethiwe luka-S)
2 × IΔn: Uhambo ≤ 150ms (ngokuphazima kweso), ≤ 200ms (uhlobo lwe-S)
5 × IΔn: Uhambo ≤ 40ms (ngokuphazima kweso), ≤ 150ms (uhlobo lwe-S)
|
Umkhakha Wezimboni |
Isicelo Esiqondile |
Imininingwane Ejwayelekile |
|
Izikhungo Zedatha |
Ukusabalalisa okuyinhloko, i-UPS bypass, ukuvikelwa kwebhasi-coupler |
250A-500A, Uhlobo A, 300mA S-uhlobo olukhethiwe, 70kA Icu, inikwe amandla ukuxhumana |
|
Izinsiza Zezempilo |
Ukusatshalaliswa okuyinhloko kwesibhedlela, izinhlelo ze-IT zezokwelapha, izinkundla zemidlalo yaseshashalazini |
100A-400A, Uhlobo A, 10mA/30mA ukuzwela okuphezulu, ukuqapha ukuzihlukanisa |
|
Izitshalo Zokukhiqiza |
Izikhungo zokulawula izimoto, imishini yokushisela, isivinini esishintshashintshayo |
160A-500A, Uhlobo B (kuma-VFDs), 300mA, 50kA Icu, uhambo lwe-elekthronikhi |
|
Izakhiwo Zokuhweba |
Ukusabalalisa okuphezulu, izitolo ezinkulu, izikhumulo zezindiza |
125A-400A, Uhlobo A, 100mA/300mA, 36kA Icu |
|
Uwoyela Negesi / Osolwandle |
Amapulatifomu angasogwini, izinsimbi zokumba, izinhlelo zamandla emikhumbi |
250A-500A, Uhlobo A, 500mA, tropicalized (T2), ukumelana nokugqwala |
I-Raw Material IQC → Ukukhiqizwa Kwe-Toroidal Transformer → Ukwenziwa Kwekesi Elibunjiwe → Umhlangano Wesistimu Yokuxhumana → Ukuhlanganiswa Kweyunithi Ye-Electronic Trip Unit → Ukulinganisa Kwemojula Yamanje → Umhlangano Oyinhloko → Ukuhlola Okuphelele → I-QC Yokugcina → Ukupakisha
|
Isiteji |
Imininingwane Yenqubo |
Amaphuzu Okulawula Ikhwalithi |
|
I-Toroidal Transformer Winding |
I-nanocrystalline noma i-ferrite core ekwazi ukufinyeleleka kakhulu (µr > 10,000), ukujikajika okunembayo kwamawindi ayisisekelo (okudlula) kanye namawindi esibili (inzwa), i-vacuum impregnation |
Ukuqinisekiswa kwejika lamandla kazibuthe, i-voltage yesibili ku-1 × IΔn ± 5%, ukumelana nokushisa > 100MΩ |
|
Ukuhlanganiswa kwe-CBCT |
Ukukhwezwa komgogodla we-toroidal kuzo zonke izikhondatha zesigaba/ezingathathi hlangothi, ukuvikela ngokumelene nezindawo zikazibuthe zangaphandle, ukuxhunywa kokudluliselwa kohambo/ugesi |
Ukuhlolwa kwebhalansi ngokulayisha okungu-6×In (alukho uhambo oluyinkathazo), ukungavikeleki kuma-harmonics wesi-3 |
|
I-Residual Current Trip Mechanism |
Ukudluliselwa kwe-polarized okuzwelayo (amandla ohambo angu-5-50mW) noma i-electronic MOSFET trigger, ukuhlangana komshini kubha yohambo enkulu |
Ukuqinisekiswa kwamandla ohambo, isikhathi sokuphendula <20ms, ukuqina kwezinga lokushisa -25°C kuya +70°C |
|
Ukukhiqizwa Kwekesi Elibunjiwe |
I-BMC thermosetting plastic (DMC-2) umjovo wokubumba umjovo, 150-180°C ikhambi, ukumelana nokulandelela okuphezulu >600V |
Ukubekezelela i-Dimensional ±0.1mm, amandla e-dielectric >15kV/mm, i-flame retardant UL 94 V-0 |
|
Umhlangano Oyinhloko Wokuxhumana |
I-Silver-plated copper (AgNi 90/10) oxhumana nabo, izingalo ezenziwe ngomshini we-CNC, ezigqama emoyeni we-nitrogen |
Ukumelana nokuxhumana <50μΩ, ukujiya kwesiliva 8-12μm (XRF), ubulukhuni HV 100-150 |
|
I-Electronic Trip Unit Programming |
Ukuvikelwa kwe-LSIG+Δ okusekelwe ku-Microprocessor, ukulayishwa kwe-firmware, ukulinganisa ijika, ukusethwa kwephrothokholi yokuxhumana |
±5% ukunemba kwamanje, ±10% ukunemba kwesikhathi, ukuqinisekiswa kwe-ZSI (Zone Selective Interlocking) |
|
Ukuhlanganiswa Kokugcina Nokulinganisa |
Ukuhlanganiswa kwesistimu yohambo lwe-thermal-magnetic noma ye-elekthronikhi enemojula yamanje eyinsalela, ukuhlangana komshini, indlela yokubamba |
Kuhlanganiswe i-overcurrent + ukuqinisekiswa kohambo lokuvuza komhlaba, i-dielectric ukumelana ne-3kV/1min |
|
Isakhi |
Ukucaciswa Kwempahla |
Amazinga Womphakeli |
Izakhiwo Eziyinhloko |
|
I-Toroidal Core (CBCT) |
I-Nanocrystalline alloy (Finemet) noma i-Mn-Zn ferrite (PC40) |
I-IEC 60404-8, JIS C 2531 |
Ukungena okuphezulu µr > 10,000, ukuphoqa okuphansi <2A/m, ukuminyana kokugeleza kwamanzi >1.2T |
|
Izwa Intambo Yekhoyili |
Intambo yethusi ene-enameled (0.05-0.1mm), Ikilasi F 155°C |
I-IEC 60317 |
I-voltage ehlukanisiwe > 1kV, ukuguquguquka > 10× ububanzi, i-solderability 390°C |
|
Ukudluliselwa Kohambo |
I-polarized latching relay, ukuzwela 5-50mW |
I-IEC 61810 |
Isikhathi sokuphendula <10ms, ukumelana nekhoyili 1-5kΩ, impilo yomshini > ukusebenza okungu-10⁶ |
|
Izindlu ezibunjiwe zekesi |
I-BMC (Inhlanganisela Yokubumba Ngobuningi) DMC-2, ifayibha yengilazi iqinisiwe |
I-IEC 60664-1, UL 94 V-0 |
Inkomba yokulandelela >600V, ukumelana nokushisa ngu-180°C, amandla okuthinta >8 kJ/m² |
|
Oxhumana Nabo Abakhulu |
Ikhopha ye-Electrolytic (Cu-ETP) + I-Silver-nickel plating (AgNi 90/10) |
I-ASTM B152 |
I-Conductivity ≥100% IACS, ukumelana nokuguguleka kwe-arc, izakhiwo zokulwa nokushisela |
|
I-Bimetallic Elements |
Inhlanganisela yensimbi ye-Inconel/passivated (ASTM TM2) |
I-ASTM B388 |
Izinga lokuchezuka 0.15-0.25mm/°C, ukuzinza kwesikhathi eside ±3%, ukumelana nokunyakaza |
|
Izingxenye Ze-elekthronikhi |
Ama-PCB ebanga lezimboni, izinzwa ze-Hall-effect, ama-ARM Cortex-M4 processors |
I-IEC 60721-3-3, IEC 61000 |
Izinga lokushisa lokusebenza -25°C kuya +70°C, i-EMC immunity Level 4, SIL 2 iyakwazi |
|
Amatheminali |
I-T2 yethusi (C11000) ene-tin plating (8-12μm) |
I-ASTM B187/B16 |
Ukuminyana kwamanje 1.2-1.5 A/mm², i-torque imelana no-5-15Nm, ukumelana nokugqwala |
|
I-Operating Mechanism |
Insimbi yasentwasahlobo (SWOSC-V) noma insimbi engagqwali (301) |
I-JIS G 3560 |
Impilo yokukhathala > imijikelezo engu-20,000, amandla e-tensile 1800-2000MPa, ukuphumula <5% |
|
Okujwayelekile |
Ububanzi |
Izilinganiso Ezisebenzayo |
|
I-IEC 60947-2 Isijobelelo B |
Ama-Circuit-breakers afaka ukuvikelwa kwamanje okuyinsalela (CBR) |
I-Industrial CBRs >80A, ukuvikelwa okuphelele |
|
EN 60947-2 |
Inguqulo yaseYurophu evumelanisiwe ye-IEC 60947-2 |
Ukumakwa kwe-CE, ukuthobela imakethe ye-EU |
|
I-GB/T 14048.2 |
Ukulingana okujwayelekile kwezwe laseShayina |
Isitifiketi se-CCC, imakethe yaseChina |
|
Isigaba sokuhlola |
Ukuhlolwa Okuthize |
Imibandela Yokwamukela |
|
Ukusebenza Kwamanje Okusele |
Isikhathi sokuhamba ngo-1×IΔn, 2×IΔn, 5×IΔn |
≤300ms, ≤150ms, ≤40ms (ngokuphazima kweso); Uhlobo lwe-S: ≤500ms, ≤200ms, ≤150ms |
|
Okungahambi ku-0.5×IΔn |
Alukho uhambo lwesikhathi sokulibaziseka esilinganiselwe esingu-2× |
|
|
I-Surge current ukumelana (8/20μs, 3kA) |
Alukho uhambo oluyinkathazo, Uhlobo A: 250A impulse, Type F: 1000A, Type B: 3000A |
|
|
Ukuvikelwa Kwamanje |
Ukunyuka kwezinga lokushisa kulinganiselwe ku-In |
Amatheminali ≤80K, ikesi ≤40K |
|
Ukuphulwa kwe-Short-circuit (Icu/Ics) |
Imisebenzi emi-3, ukuphazamiseka okuyimpumelelo, ukululama kwe-dielectric |
|
|
Ukuqinisekiswa kwejika lohambo (L-S-I) |
±10% ukunemba kwamanje, ±20% ukunemba kwesikhathi |
|
|
Izakhiwo zeDielectric |
I-Power-frequency ukumelana (2.5kV-3.5kV/1min) |
Akukho ukuhlukana, akukho flashover |
|
I-Ipulse ukumelana (8kV 1.2/50μs) |
Akukho ukukhipha okuphazamisayo |
|
|
Mechanical & Environmental |
Ukukhuthazela ngomshini (10,000-20,000 imijikelezo) |
<5% ipharamitha drift, akukho ukwehluleka |
|
Ukuzivikela kwe-EMC (uchungechunge lwe-IEC 61000-4) |
Akukho ukuphazamiseka okuvela ekuphazamisekeni kwemisebe/okwenziwe |
|
Okubalulekile |
Izinto Zokuhlola |
Uhlelo lwesampula |
Izisetshenziswa |
|
I-Toroidal cores |
I-magnetic permeability, i-saturation flux, ukulahlekelwa okuyinhloko |
Iqoqo ngalinye, ukuhlolwa kwejika le-B-H |
I-B-H analyzer, i-impedance analyzer |
|
Intambo yokuzwa |
Ububanzi, ukujiya kwe-insulation, i-voltage yokuphuka |
I-AQL 0.65 |
I-Micrometer, i-dielectric tester |
|
I-BMC plastic compound |
Okuqukethwe kwengilazi, i-viscosity, izici zokwelapha, inkomba yokulandelela |
Iqoqo ngalinye, ukuhlolwa kwe-COA + |
I-Rheometer, i-DSC analyzer, amathuluzi okuhlola okulandela umkhondo |
|
Isixazululo se-Silver Plating |
Ukugxila kwensimbi, i-pH, ukungcola |
Ukuqapha kwansuku zonke |
I-spectrometer yokumuncwa kwe-athomu |
|
Izingxenye ze-elekthronikhi |
Ukuhlolwa komsebenzi, ukuqinisekiswa kwepharamitha, inguqulo ye-firmware |
100% AOI, 5% ukusebenza |
Imitha ye-LCR, i-oscilloscope, ukuskena komngcele |
|
Isiteshi |
Lawula Amapharamitha |
Imvamisa |
Indlela |
|
I-Toroidal transformer winding |
Ishintsha isilinganiso, i-inductance, ukumelana nokufakwa kwe-insulation |
Wonke amayunithi |
Imitha ye-LCR, i-insulation tester |
|
Umhlangano we-CBCT |
Ukuhlolwa kwebhalansi ngomthwalo olinganiselwe, ukungatheleleki kuma-harmonics |
Njalo ngamayunithi ayi-100 |
Ukuhlolwa komjovo okuyisisekelo, ijeneretha ye-harmonic |
|
Ukulinganisa kwamanje okusele |
Umkhawulo wohambo e-IΔn, isikhathi sokuphendula, okungelona uhambo ngo-0.5×IΔn |
Wonke amayunithi |
Isihloli se-RCD esizenzakalelayo (i-0.5-1000mA ehlelekayo) |
|
Umhlangano oyinhloko wokuxhumana |
Igebe lokuxhumana, ingcindezi, ukuqondanisa, ukumelana |
Njalo ngamayunithi ayi-100 |
I-gauge yokuphoqelela, i-micro-ohmmeter |
|
Ukuhlanganiswa kokugcina |
Kuhlanganiswe i-overcurrent + ukuqinisekiswa kohambo lokuvuza komhlaba |
Wonke amayunithi |
Ibhentshi lokuhlola elihlanganisiwe (umjovo oyinhloko + ukulingisa ukuvuza) |
|
Into yokuhlola |
Okujwayelekile |
Usayizi Wesampula |
|
Isikhathi sohambo samanje esisele |
1×IΔn, 2×IΔn, 5×IΔn nge-IEC 61008/61009 |
100% |
|
Ukuhlolwa okungelona uhambo ku-0.5×IΔn |
2 × isikhathi sokulibaziseka esilinganiselwe |
100% |
|
Ijika lohambo lwamanje |
1.05×In, 1.25×In, 5×In, 10×In |
100% |
|
I-Dielectric ukumelana ne-voltage |
2.5kV AC/1min |
100% |
|
Ukumelana ne-insulation |
>100MΩ @ 500V DC |
100% |
|
Xhumana nokumelana |
<50μΩ isigxobo ngasinye |
100% |
|
Ukuqinisekiswa kwe-torque |
Ukuqiniswa kwetheminali ngokwencazelo ngayinye |
100% |
|
Ukuhlola okubonakalayo nobukhulu |
Amaphutha ayiziro kubukhulu obubucayi |
100% |
|
Imaka unaphakade |
Ukusula i-solvent, ukuhlolwa kwe-abrasion |
I-AQL 1.0 |
|
Ubuqotho bokupakisha |
Ukuhlolwa kokudedela, ukudlidliza (ISTA 3A) |
Ngamunye |
|
Isigaba Sezisetshenziswa |
Ukucaciswa komshini |
Umsebenzi |
Amandla |
|
Toroidal Winding Machines |
I-toroidal winding ezenzakalelayo enokulawula ukungezwani |
I-CBCT primary/secondary winding, ukunemba kwesendlalelo |
5,000 ama-transformer/ngosuku |
|
I-Core Annealing Furnace |
I-vacuum annealing ene-nitrogen emoyeni |
Ukwelashwa kokushisa okuyisisekelo kwe-Nanocrystalline, ukukhululeka kwengcindezi |
2,000 cores/inqwaba |
|
Ukubunjwa komjovo |
300-tons BMC thermosetting press |
Izindlu ze-CBR, i-arc chute, amabhlogo wetheminali |
3,000 amacala/ngosuku |
|
CNC Machining |
5-eksisi isikhungo semishini eqondile |
Ukunemba komshini wokuxhumana, amajiyometri ayinkimbinkimbi |
8,000 amasethi othintana naye/ngenyanga |
|
Ukwelashwa Okungaphezulu |
I-automated silver plating line |
I-plating yokuxhumana 8-12μm, ukufana kogqinsi ±1μm |
4,000 kg/ngosuku |
|
Umhlangano |
Amaseli okuhlanganisa abasebenzi |
Ukuhlanganiswa kwe-Mechanism, ukuhlanganiswa kwe-CBCT, ukulinganisa |
1,500 amayunithi / ngosuku umugqa ngamunye |
|
Izisetshenziswa zokuhlola |
Ibhentshi lokuhlola elihlanganisiwe le-CBR |
I-overcurrent ehlanganisiwe + ukuqinisekiswa kwamanje okuyinsalela |
300 amayunithi / ihora |
|
|
Igumbi lokuhlola le-EMC (3m/10m, Teseq) |
Ukuhlolwa kokugomela/ukukhishwa kwe-emission kumayunithi kagesi |
50 amayunithi / ngosuku |
|
Isigaba somkhiqizo |
Amandla Wanyanga zonke |
Isikhathi Esijwayelekile Sokuhola |
Amandla Woku-oda Okuphuthumayo |
|
I-CBR 4P (16A-125A) |
10,000 amayunithi |
4-5 amaviki |
Izinsuku ezi-3 (izingxenye zesitoko) |
|
I-CBR Industrial (160A-400A) |
8,000 amayunithi |
4-5 amaviki |
5 izinsuku |
|
I-CBR Heavy Industrial (630A-800A) |
3,000 amayunithi |
4-5 amaviki |
izinsuku ezingu-7 |
|
Ukulungiselela ngokwezifiso (i-IΔn ekhethekile, amajika) |
Isisekelo sephrojekthi |
5-6 amaviki |
2 amasonto |
|
Umnyango |
Abasebenzi |
Uchwepheshe |
Izibopho |
|
Ubunjiniyela be-R&D |
5 onjiniyela |
Ubuchwepheshe bamanje obusalelayo, idizayini yezinzwa kazibuthe, amasistimu ashumekiwe, amandla kagesi |
Ukuthuthukiswa okusha kwe-CBR, uhlobo olusha lwe-B/F/B+, iphothifoliyo yelungelo lobunikazi (amalungelo obunikazi angama-40+) |
|
Ubunjiniyela Bezinqubo |
18 onjiniyela |
Ukukhiqizwa kwe-Toroidal transformer, ukubumba kwe-BMC, ukuhlanganiswa okunembayo, ukukhiqiza okuthambile |
Ukuthuthukiswa kokukhiqiza, imibhalo ye-SOP, ukuthuthukiswa kwesivuno (>99.5%) |
|
Ukuhlola Nokuqinisekisa |
15 onjiniyela |
Ukuhlolwa kwamanje okuphezulu, ukulingiswa kwamanje okusele, i-EMC, ukuhlolwa kwemvelo |
Uhlobo lokuxhumanisa ukuhlola (IEC 60947-2 Annex B, IEC 61008/61009), ukuhlaziywa kokwehluleka |
|
Ubunjiniyela bohlelo lokusebenza |
10 onjiniyela |
Ukuxhumana okukhethiwe, izikimu zokuvikela ukuvuza komhlaba, izinhlelo zokusebenza ze-EV/ezivuselelekayo |
Ukwesekwa kobuchwepheshe bekhasimende, izifundo zokucwasa, ukugunyazwa kwesayithi |
|
Ukuqinisekisa ikhwalithi |
30 ochwepheshe |
ISO 9001, ISO 14001, ukulawulwa kwenqubo yezibalo, ilabhorethri ye-metrology |
Ukucwaningwa kwabahlinzeki, ukuhlolwa kwenqubo, isenzo sokulungisa, ukuphathwa kokulinganisa |
|
Isitifiketi |
Umzimba Wokukhipha |
Ububanzi |
Ukuba semthethweni |
|
ISO 9001:2015 |
ZHONGDA HUAYUAN |
Uhlelo lokuphatha ikhwalithi |
Ukuqapha konyaka |
|
Ukuhlolwa kohlobo lwe-IEC 60947-2 Isijobelelo B |
I-EUR |
Ukusebenza kwezimboni ze-CBR |
Ngochungechunge lomkhiqizo ngamunye |
|
CE Ukumaka |
Umzimba Owazisiwe |
Ukufinyelela emakethe ye-EU |
Kuncike kumklamo |
|
I-CCC (China) |
I-CQC |
Isitifiketi esiyimpoqo saseShayina |
Ukuqinisekiswa kweminyaka emi-5 |
|
Uhlelo lwe-CB |
IECEE |
Isitifiketi samazwe ngamazwe |
Ngochungechunge lomkhiqizo ngamunye |
Indawo yethu yokukhiqiza imeleIminyaka engama-40 yobungcweti kubuchwepheshe obunsalela bamanje kanye nokuvikela ukuvuza komhlaba, ukuletha ama-CBR adlula amazinga omhlaba ngokusebenzisa:
Ubuchwepheshe be-Toroidal transformer: Ukukhiqizwa kwangaphakathi kwe-nanocrystalline core, ukunemba kwe-automation, kanye nokuhlola okuphelele kwe-CBCT okuqinisekisa <±5% ukunemba kokuzwela
Ukuhlanganiswa okuqondile: Ukusuka ekucutshungulweni kwezinto ezibalulekile kuye ekuhlanganisweni kokugcina, ukulawula okuphelele kwezingxenye ezibalulekile (iziguquli ze-toroidal, amayunithi ohambo lwe-elekthronikhi, amakesi abunjiwe)
Ingqalasizinda yokuhlola ethuthukile: $3M+ etshalwe ezinhlelweni zokuhlola ezihlanganisiwe ze-CBR ezikwazi ukuqinisekiswa kwamanje okudlulele kanye nensalela ngasikhathi sinye, ukuhlolwa kokuzwela kohlobo lwe-B DC, nokuhambisana ne-EMC
Isu lesitifiketi somhlaba wonke: Ukuthobela okujwayelekile okuvumela ukungena ezimakethe okungenazihibe emazweni angu-100+ ngaphandle kokuhlolwa okungafuneki
Ngokucaciswa kobuchwepheshe, izifundo zokudidiyela ezikhethiwe, isiqondiso sesicelo sohlobo B, noma ukuhlela ukuhlolwa kwefekthri, ithimba lethu lonjiniyela lihlinzeka ngokubonisana okuqondile ukuze liqinisekise ukuthi i-architecture yakho yokuvikela ukuvuza komhlaba ihlangabezana kokubili izidingo zokuphepha kwezisebenzi kanye nezinjongo zokuqhubeka nokusebenza.