Imikhiqizo
I-AC Type Circuit Breaker enomsebenzi wamanje oyinsalela
  • I-AC Type Circuit Breaker enomsebenzi wamanje oyinsalelaI-AC Type Circuit Breaker enomsebenzi wamanje oyinsalela
  • I-AC Type Circuit Breaker enomsebenzi wamanje oyinsalelaI-AC Type Circuit Breaker enomsebenzi wamanje oyinsalela

I-AC Type Circuit Breaker enomsebenzi wamanje oyinsalela

Model:DAM1L
I-CDADA, umkhiqizi ochwepheshe oneminyaka engu-40+ yesipiliyoni, anganikeza ikhwalithi ephezulu ye-AC TYPE Circuit Breaker ne-Residual Current Operation (DAM1L). I-4P, 10–500A, CE/CB/SEMKO iqinisekisiwe. I-CBR yohlobo lwe-AC lwangempela lokuvuza kwe-sinusoidal kuphela. Ilungele ukuvikela umlilo/ukuvikela komuntu siqu kwezindawo zokuhlala nezimboni.

Hlangana nezindinganiso zokuphepha zomhlaba wonke nge-CDADA DAM1L AC Type Circuit Breaker With Residual Current Operation a high-integrity earth leakge MCCB eklanywe yi-Shanghai DADA Electric CO., LTD. ukuze uthole ukuvikelwa okuthembekile kumaphutha aphansi we-sinusoidal AC kuphela (nge-IEC 60755 ngayinye).

Idizayinelwe njengekhefu elibunjiwe le-4P elilinganiselwe ngo-10A kuya ku-500A ku-400V/415V, lihlanganisa ukulayishwa okuningi, isifunda esifushane, nokuvikelwa kwamanje okuyinsalela kuyunithi eyodwa ehlangene. Igunyazwe ku-CE, CB, kanye ne-SEMKO, i-DAM1L ilungele izinhlelo zokusebenza lapho ukutholwa kokuvuza kwe-AC okumsulwa kwanele njengezintambo zokuhlala ezijwayelekile, amasekhethi okukhanyisa, noma imithwalo yezimoto ngaphandle kwamadrayivu e-electronic.

Nge-I△n elungisekayo (30mA–1000mA), ama-electronics asebenza ngezigaba eziningi (okusebenza phansi aze afike ku-50V), nokuhlukaniswa kwe-arc okuqinile, iletha ukusebenza okuhlulekayo ezakhiweni, emigudu, nengqalasizinda—ngenkathi ithobelana ngokuqinile nezidingo ze-RCD zohlobo lwe-AC.

AC Type Circuit Breaker with Residual Current Operation

Imininingwane Ebalulekile

Uhlobo Lomkhiqizo: I-AC TYPE Residual Current Circuit Breaker (RCBO/MCCB ihlanganisiwe)
Uchungechunge lwamamodeli: I-DAM1L
Izigxobo: 4P (okujwayelekile)
Kukalwe Okwamanje (Kuphakathi): 10A – 500A
I-Voltage elinganiselwe: 400V / 415V AC, 50Hz
I-Insulation Voltage (Ui): 400V (<160A), 690V (>250A)
Uhlobo Lwamanje Olusele: I-AC TYPE - iphendula kuphela ekuvuzeni okubushelelezi kwe-sinusoidal AC
I△n Izilungiselelo: I-30mA, 100mA, 300mA, 500mA, 1000mA (iyalungiseka esizeni)
Isikhathi Sohambo: Ngokushesha noma ukubambezeleka (0.05s–0.8s, kuye ngesilungiselelo)
Ukuphula Amandla: Izinhlobo ze-B/S/H (kufika ekuqhekekeni okuphezulu kokuthi >160A)
Izitifiketi: CE, CB, SEMKO


Izici Eziyinhloko:

★ Isekethe ye-RCD enezigaba eziningi → isebenza ku-≥50V

★ Inkinobho ye-Push-to-test

★ Hlukanisa othintana nabo abakhulu & be-arcing

★ Uhambo kazibuthe olulungisekayo (0.8–1.0×In)

★ Ukuzivikela okuqinile kwe-EMI

★ Ukusekelwa okugcwele kwesesekeli (uhambo lwe-shunt, oxhumana nabo be-aux, isibambo esijikelezayo)


Kungani Khetha i-CDADA AC TYPE CBR?

★ Ukuhambisana Kweqiniso Kohlobo lwe-AC

Ngokungafani nemishini yohlobo lwe-A "yomhlaba wonke", i-CDADA yohlobo lwe-AC-CBR ilungiselelwe kuphela ukuvuza kwe-sinusoidal AC-inikeza ukusebenza kahle kwezindleko eziphezulu lapho imithwalo ye-elekthronikhi (isb., ama-VFD, ama-SMPS) ingekho.

★ I-Fail-Safe Power Design

Imishini kagesi ye-RCD idonsa amandla kuzo zonke izigaba, iqinisekisa ukusebenza ngisho nangesikhathi sokulahlekelwa kwesigaba esisodwa noma i-undervoltage enzima—inzuzo ebalulekile ngaphezu kwabaqhudelana besigaba esisodwa.

★ Izindima Zokuphepha Ezimbili

● 30mA: Ihlangabezana ne-IEC ukuze ivikeleke ngokomuntu siqu

● 100mA–1000mA: Ivimbela imililo engasebenzi kahle kumakhebuli namabhokisi okuhlanganisa

★ Field-Adjustable Protection

Shuna ukuzwela nokubambezeleka kwesikhathi ukuze kufane nezimo zokufaka—ugwema uhambo oluyinkathazo kuyilapho ugcina ukuthotshelwa kwekhodi.

★ I-Industrial-Grade Integration

Ihlanganisa i-MCCB ne-RCD kuyunithi eyodwa evaliwe-ukonga isikhala, ukunciphisa amaphutha ezintambo, nokuqinisekisa ukusebenzisana okuphelele.

★ Yamukelwa Emhlabeni Wonke

Nge-CE, CB, kanye ne-SEMKO, igunyazwe ukuthi lisetshenziswe kulo lonke elaseYurophu, eMpumalanga Ephakathi, e-Afrika nase-Asia—lilungele abakhi bamaphaneli abagxile ekuthekeliseni.

★ Imikhiqizo yethu inikelwe amaphrojekthi egridi kagesi, izitshalo zezimboni, izakhiwo zezentengiselwano, namaphrojekthi wengqalasizinda emazweni amaningi.

AC Type Circuit Breaker with Residual Current Operation

★ Sitshala imali ngokuqhubekayo ku-R&D, siqapha amazinga omhlaba kanye nezimakethe, futhi sibambisana nochwepheshe bemboni ukuze sithuthukise iphothifoliyo yethu yomkhiqizo.


Izicelo Ezijwayelekile

AC Type Circuit Breaker with Residual Current OperationIzakhiwo Zokuhlala: Amaphaneli amakhulu noma ama-sub-circuits (ukukhanyisa, amasokhethi) ngaphandle kwe-electronics

AC Type Circuit Breaker with Residual Current OperationUkukhanyisa Kwezentengiselwano: Amasekhethi osilingi wasehhovisi, amalambu ephaseji

AC Type Circuit Breaker with Residual Current OperationImithwalo Yezimoto Yendabuko: Amaphampu, amafeni, ama-compressor (okungashayelwa i-VFD)

AC Type Circuit Breaker with Residual Current OperationIngqalasizinda: Izibani zomhubhe, amakhabethe emigwaqo, amagumbi emishini ye-elevator

Amaphrojekthi Azwela Izindleko: Lapho ama-RCD ohlobo lwe-A engadingeki futhi ecaciswe ngokweqile


FAQ

Q1: Isho ukuthini i-“AC TYPE” kudivayisi yamanje eyinsalela?

I-A1: I-AC TYPE CBRs iphendula kuphela kuma-currents asele ashintshashintshayo abushelelezi, isb. Abayiboni i-DC enyakazayo kuma-electronics njengamashaja efoni noma abashayeli be-LED. Sebenzisa uhlobo luka-A uma imithwalo enjalo ikhona.


Q2: Ngingakwazi ukusebenzisa le AC CBR 63A ngesekhethi yesokhethi yasekhaya?

I-A2: Kuphela uma isifunda singenazo izinto zikagesi (isb., imithwalo eqinile eqinile efana nezibani ze-incandescent noma amaketela esitayela esidala). Emakhaya esimanje anama-TV, amakhompyutha aphathekayo, noma izibani ze-LED, khetha i-RCD yohlobo olu-A esikhundleni salokho.


Q3: Kungani ngingakhetha uhlobo lwe-AC kunohlobo lwe-A?

I-A3: Izindleko eziphansi kanye nokuvikeleka okuphezulu ekukhubekeni okungamanga endaweni ye-AC kuphela. Uma isistimu yakho ingenazo izinto zokulungisa izinto, iziguquli, noma izisetshenziswa zamandla zemodi yokushintsha, uhlobo lwe-AC lwanele futhi luyonga kakhulu.


I-Q4: Ingabe iyasebenza uma isigaba esisodwa sihluleka?

A4: yebo! Isekethe ye-RCD inikwa amandla ukunikezwa kwezigaba eziningi, ngakho-ke ihlala isebenza ngisho nangesikhathi sokulahlekelwa kwesigaba noma ukwehla kwamandla kagesi ukuya ku-50V-ukuqinisekisa ukuvikelwa kokuvuza okuqhubekayo.


Q5: Kungani ukhethe i-CDADA yohlobo lwe-AC Circuit Breaker enomsebenzi wamanje oyinsalela?

A5: I-CDADA inikeza:

● Idizayini yohlobo lwe-AC evumelana ne-IEC 60755 yangempela

● I-MCCB ehlanganisiwe + ne-RCD kuyunithi eyodwa (azikho izinkinga zokusebenzisana)

● Ama-electronics asebenza ngezigaba eziningi ukuze athembeke

● Ukulungiswa kwendawo kwe-I△n nokubambezeleka kwesikhathi

● Izitifiketi zomhlaba wonke (CE/CB/SEMKO) ezinamanani avumelana ne-OEM

Hot Tags: I-AC Type Circuit Breaker Enokusebenza Kwamanje Okusele, e-China, Umkhiqizi, Umphakeli, Imboni
Thumela Uphenyo
Ulwazi Lokuxhumana

Vula Isixazululo Sakho Sikagesi Esingokwezifiso Emahoreni angama-24!

Kungani Ubuza Nomkhiqizi WaseShayina Osezingeni Eliphezulu?

✅ Amanani Aqondile Embonini

Nciphisa izindleko ze-middleman! Njengefekthri enesitifiketi se-ISO 9001 e-China, siletha ama-MCCB e-premium, ama-MCB, nama-solar DC breaker ngamanani ancintisanayo—okusekelwe yi-CE, KEMA, kanye nezitifiketi ze-ASTA.

✅ Iminyaka engu-40+ Yobuchwepheshe be-OEM/ODM

Shintsha ama-casings, amalebula, noma imininingwane yobuchwepheshe kalula. Ithimba lethu le-R&D (amalungelo obunikazi angama-60+) liphatha:

Izilinganiso zangokwezifiso ze-voltage/zamanje

Ukupakisha okunophawu

I-prototyping esheshayo (amasampula ezinsukwini eziyi-7)

✅ 3 Million+ Amayunithi Amandla Wonyaka

Alikho i-oda elikhulu kakhulu noma eliphuthumayo! Iziqinisekiso zethu zezitshalo ezingama-52,400㎡:

◆ Izikhathi zokuhola zezinsuku eziyi-15 zama-oda amaningi

◆ Ama-MOQ aguquguqukayo

◆ Ukuhlolwa okuqinile kwe-ASTM/UL

✅ Ukuthobelana Kwembulunga yonke, I-Zero Hassle

Sixazulula izithiyo zokuthumela ngaphandle zamazwe angama-45+:

Imibhalo ye-RoHS/REACH

Izitifiketi eziqondene nesifunda

Ama-Solar DC amaphrojekthi aluhlaza we-EU

X
Sisebenzisa amakhukhi ukukunikeza umuzwa ongcono wokuphequlula, ukuhlaziya ithrafikhi yesayithi nokwenza okuqukethwe kube ngokwakho. Ngokusebenzisa le sayithi, uyavumelana nokusebenzisa kwethu amakhukhi.Inqubomgomo yobumfihlo
YenqabaYamukela