Imikhiqizo
Ukukhishwa kwe-MCB Shunt
  • Ukukhishwa kwe-MCB ShuntUkukhishwa kwe-MCB Shunt
  • Ukukhishwa kwe-MCB ShuntUkukhishwa kwe-MCB Shunt
  • Ukukhishwa kwe-MCB ShuntUkukhishwa kwe-MCB Shunt
  • Ukukhishwa kwe-MCB ShuntUkukhishwa kwe-MCB Shunt
  • Ukukhishwa kwe-MCB ShuntUkukhishwa kwe-MCB Shunt

Ukukhishwa kwe-MCB Shunt

Khetha i-CDADA njengomphakeli wakho we-MCB Shunt Release, lo mkhiqizo ungowokulawula kude kwama-circuit breaker akho e-DAB7-63. Itholakala ku- 24V ukuya ku-400V AC/DC, iqinisekisa ukusebenza okuthembekile phakathi kwebanga elibanzi lamandla kagesi. Ilungele ukuvala shaqa kwesimo esiphuthumayo kanye nezinhlelo ezizenzakalelayo. Kulula ukuyifaka, ehambisana ngokuqondile nochungechunge lwe-CDADA lwe-DAB7—awekho ama-adaptha engeziwe adingekayo.

I-CDADA iyimboni enokwethenjelwa kusukela ngo-1983, i-MCB Shunt Release yethu iklanyelwe ukuhlinzeka ngesixazululo esinokwethenjelwa sokulawula ukude ama-breaker circuit e-DAB7-63. Kungakhathaliseki ukuthi udinga umsebenzi wokumisa izimo eziphuthumayo noma ukuhlanganiswa kusistimu ezenzakalelayo, ukukhishwa kwethu kwe-shunt kunikeza ukusebenza nokuvumelana nezimo okudingayo.

Mcb Shunt ReleaseMcb Shunt Release

Amaphuzu Avelele Womkhiqizo

★ Inhloso: Ukunqanyulwa okukude kwama-MCB ngokuvala shaqa okuphuthumayo noma i-automation yesistimu.

★ I-Voltage Range: Ihambisana ne-AC 50Hz (24V kuya ku-400V) kanye ne-DC (24V kuya ku-220V) ukunikezwa.

★ Ukuthembeka: Isebenza ngokuthembekile phakathi kuka-70% kuya ku-110% wevolthi elinganiselwe.

★ Ukuvumelana: Idizayinelwe ngokuqondile ama-DAB7-63 MCBs—awekho ama-adaptha adingekayo.

★ Ukulula Ukufaka: Inqubo yokufaka esheshayo neqondile.

★ Isincomo Sethu: Ukuze usebenze kahle, qinisekisa ukuthi i-voltage yokulawula esetshenzisiwe iwela phakathi kwebanga elishiwo lika-70% kuya ku-110% Us.

Mcb Shunt ReleaseMcb Shunt Release

Imininingwane Yezobuchwepheshe

Isici

Ukucaciswa

I-rated Control Source Voltage (Thina)

I-AC: 50Hz, 24V kuya ku-400V; I-DC: 24V kuya ku-60V, 110V kuya ku-220V

Ububanzi Bamandla Okusebenza

70% kuya ku-110% wethu

I-breaker Ehambisanayo

Uchungechunge lwe-CDADA DAB7-63 kuphela

Umhlahlandlela Wokufaka Nokusebenzisa

Ukuze uthole okuningi ku-CDADA MCB Shunt Release yakho, landela lezi zinyathelo:

★ Qinisekisa Ukuhambisana: Qinisekisa ukuthi i-voltage yokulawula ifana nezincazelo zokukhululwa kwe-shunt.

★ Ukukhweza: Namathisela ukukhululwa kwe-shunt ngokuqondile ohlangothini lwesobunxele lwe-DAB7-63 MCB.

★ Izintambo: Xhuma isignali yakho yokulawula kumatheminali aqokiwe ekukhululweni kwe-shunt.

★ Sebenzisa izintambo ezivikelekile amabanga amade ukuze ugweme ukuphazamiseka.

★ Ukuhlola: Faka i-voltage yokulawula ukuze uqinisekise ukuthi i-breaker ivuleka njengoba kulindelekile.

★ Ithiphu Yokulungisa: Njalo hlola izintambo ezixhunywe kuzo ukuze uthole izimpawu zokuguga noma zokonakala. Gcina indawo ezungeze ukukhishwa kwe-shunt ihlanzekile futhi ingenalo uthuli ukuze uqinisekise ukusebenza okuthembekile.

I-Wiring Diagram Uhlolojikelele

Umdwebo wezintambo we-CDADA MCB Shunt Release uqondile:

★ Isiginali Yokulawula: Xhuma idivayisi yakho yokulawula yangaphandle kumatheminali anikeziwe.

★ I-breaker: Ukukhishwa kwe-shunt kuhlanganiswe ngokuzenzakalelayo kumshini wokuvula wephula, okuqinisekisa ukunqanyulwa okusheshayo uma kubaliwe.

★ Inothi Lokufaka: Njalo hlola kabili izintambo zakho ngaphambi kokufaka amandla ukuze ugweme noma yiziphi izingozi ezingaba khona.

imibuzo ejwayelekile ukubuzwa

Q1: Kusetshenziselwa ini ukukhishwa kwe-MCB shunt?

I-A1: Ukukhishwa kwe-MCB shunt kuvumela ukunqanyulwa okukude kwe-breaker circuit, okungaba bucayi ekumiseni okuphuthumayo noma ukuhlanganiswa kumasistimu azenzakalelayo.


Q2: Ngingakwazi ukusebenzisa lokhu kukhishwa kwe-shunt nganoma iyiphi i-MCB?

A2: Cha, i-CDADA MCB Shunt Release yakhelwe ngokukhethekile ukusetshenziswa nochungechunge lwe-DAB7-63. Ngeke ilingane namanye amabhrendi ngaphandle kokuguqulwa.


Q3: Ingabe ukukhishwa kwe-shunt kulungele kokubili izinhlelo zokusebenza ze-AC ne-DC?

I-A3: Yebo, ukukhishwa kwethu kwe-shunt kusekela kokubili izinhlelo zokusebenza ze-AC (24V kuya ku-400V) kanye ne-DC (24V kuya ku-220V), ihlinzeka ngokuguquguquka ezindaweni ezihlukahlukene.


Q4: Kungani ukhetha ukukhululwa kwe-CDADA shunt ngaphezu kwabanye?

A4: Kwa-CDADA, sibeka phambili:

● Ukuqinisekisa Ikhwalithi: Iyunithi ngayinye ihlolwa kanzima.

● Ukufaka kalula: Ukusebenzisana okuqondile nama-DAB7-63 MCB—awekho ama-adaptha engeziwe adingekayo.

● Usekelo Lwekhasimende: Usizo oluqondile oluvela ethimbeni lethu elinolwazi.

● Ukusebenza Kwezindleko: Amanani ancintisanayo ngaphandle kokufaka engozini ikhwalithi.

Inothi lokugcina elivela ku-CDADA

Ukukhetha ukukhululwa kwe-shunt okulungile kungathuthukisa kakhulu ukuphepha nokusebenza kwamasistimu akho kagesi. Nge-CDADA, awugcini nje ngokuthola ingxenye—uzuza uzakwethu ozinikele ekwenzeni okuhle kuyo yonke imininingwane. Masikusize uzuze ukuthula kwengqondo ngezixazululo zethu ezithembekile nezisebenziseka kalula.

Hot Tags: Ukukhishwa kwe-MCB Shunt, e-China, Umkhiqizi, Umhlinzeki, Imboni
Thumela Uphenyo
Ulwazi Lokuxhumana

Vula Isixazululo Sakho Sikagesi Esingokwezifiso Emahoreni angama-24!

Kungani Ubuza Nomkhiqizi WaseShayina Osezingeni Eliphezulu?

✅ Amanani Aqondile Embonini

Nciphisa izindleko ze-middleman! Njengefekthri enesitifiketi se-ISO 9001 e-China, siletha ama-MCCB e-premium, ama-MCB, nama-solar DC breaker ngamanani ancintisanayo—okusekelwe yi-CE, KEMA, kanye nezitifiketi ze-ASTA.

✅ Iminyaka engu-40+ Yobuchwepheshe be-OEM/ODM

Shintsha ama-casings, amalebula, noma imininingwane yobuchwepheshe kalula. Ithimba lethu le-R&D (amalungelo obunikazi angama-60+) liphatha:

Izilinganiso zangokwezifiso ze-voltage/zamanje

Ukupakisha okunophawu

I-prototyping esheshayo (amasampula ezinsukwini eziyi-7)

✅ 3 Million+ Amayunithi Amandla Wonyaka

Alikho i-oda elikhulu kakhulu noma eliphuthumayo! Iziqinisekiso zethu zezitshalo ezingama-52,400㎡:

◆ Izikhathi zokuhola zezinsuku eziyi-15 zama-oda amaningi

◆ Ama-MOQ aguquguqukayo

◆ Ukuhlolwa okuqinile kwe-ASTM/UL

✅ Ukuthobelana Kwembulunga yonke, I-Zero Hassle

Sixazulula izithiyo zokuthumela ngaphandle zamazwe angama-45+:

Imibhalo ye-RoHS/REACH

Izitifiketi eziqondene nesifunda

Ama-Solar DC amaphrojekthi aluhlaza we-EU

X
Sisebenzisa amakhukhi ukukunikeza umuzwa ongcono wokuphequlula, ukuhlaziya ithrafikhi yesayithi nokwenza okuqukethwe kube ngokwakho. Ngokusebenzisa le sayithi, uyavumelana nokusebenzisa kwethu amakhukhi.Inqubomgomo yobumfihlo
YenqabaYamukela