Imikhiqizo
Ukukhishwa kwe-MCCB Shunt
  • Ukukhishwa kwe-MCCB ShuntUkukhishwa kwe-MCCB Shunt
  • Ukukhishwa kwe-MCCB ShuntUkukhishwa kwe-MCCB Shunt
  • Ukukhishwa kwe-MCCB ShuntUkukhishwa kwe-MCCB Shunt

Ukukhishwa kwe-MCCB Shunt

Zitholele I-CDADA MCCB Shunt Release ukuze uthole isilawuli kude semisebenzi yakho ye-circuit breaker. Itholakala ku-220V AC/DC, ilungele izinhlelo zokusebenza ezidinga ukunqanyulwa ngokushesha. Kulula ukuyifaka, ngezintambo ezixhunywe ngaphambilini ezivela efekthri—vele ungeze isignali yakho yokulawula. Ilungele izinhlelo zokuphepha zezimboni nezentengiso.

I-Shanghai DADA Electric CO., LTD. ingumkhiqizi onokwethenjelwa e-China, futhi inomkhiqizo wayo, i-CDADA. Siyakuqonda ukubaluleka kokuba nezingxenye zikagesi ezithembekile nezisebenza kahle ezingalawulwa ukude ukuze kuqinisekiswe ukuphepha nobuqotho besistimu. Yingakho sithuthukise i-CDADA MCCB Shunt Release, eklanyelwe ukuhlangabezana nalezi zidingo.

Kungakhathaliseki ukuthi ungunjiniyela ofuna ukuthuthukisa izici zokuphepha zesistimu yakho noma umphathi wokuthenga ofuna izingxenye zekhwalithi ephezulu, ukukhishwa kwethu kwe-shunt kunikeza ukwethembeka nokusebenzisa kalula okudingayo.

Mccb Shunt ReleaseMccb Shunt ReleaseMccb Shunt Release

Amaphuzu Avelele Womkhiqizo

★ Inhloso: Ukusebenza okukude kwama-MCCB (Ama-Molded Case Circuit Breakers) ukuze anqanyulwe ngokushesha.

★ I-Voltage Range: Ihambisana ne-AC 50Hz 220V/380V kanye ne-DC 110V/220V impahla.

★ I-Pre-Wired Convenience: Iza nezintambo zangaphakathi ezilungiselelwe efekthri, okushiya kuphela ukuxhumana kwangaphandle komsebenzisi.

★ Ukufaka Okulula: Xhuma amasignali akho okulawula kumatheminali aqokiwe—akukho ukusetha okuyinkimbinkimbi okudingekayo.

★ Ukusebenza Okunokwethenjelwa: Kuklanyelwe umsebenzi osheshayo, ukuqinisekisa izikhathi zokuphendula ngokushesha phakathi nezimo ezibucayi.

★ Isincomo Sethu: Ukuze usebenze kahle, hlala uqondanisa isilinganiso sikagesi sokukhishwa kwe-shunt nezicaciso zokulawulwa kwamandla kagesi kwe-MCCB yakho.

Imininingwane Yezobuchwepheshe

Isici

Ukucaciswa

Isicelo

Isilawuli kude sokuvulwa kwe-MCCB

Supply Voltage Range

(0.7 - 1.1) x Nathi

I-Rated Control Supply Voltage (Thina)

I-AC: 220V, 380V; I-DC: 110V, 220V

Ukulahlekelwa Amandla

150V (kokubili i-AC ne-DC)

Izinombolo zetheminali

p3, p4

Izintambo

Ilungiselelwe imboni ngaphandle kwemigqa ephukile

Umhlahlandlela Wokufaka Nokusebenzisa

Ukuze uthole okuningi ku-CDADA MCCB Shunt Release yakho, landela lezi zinyathelo:

★ Qinisekisa Ukuhambisana: Qinisekisa ukuthi isilinganiso sikagesi sokukhishwa kwe-shunt sifana nesilawuli se-MCCB yakho.

★ Xhuma Isiginali Yokulawula: Sebenzisa inkinobho enikeziwe (SB2) noma idivayisi yakho yokulawula ukuze uxhume kumatheminali P3 kanye ne-P4.

★ Hlola Imidwebo Yezintambo: Bheka umdwebo ofakiwe lapho kuphela imigqa ephukile idinga ukuxhunywa ngumsebenzisi-zonke ezinye izintambo zilungiselelwe efekthri.

★ Umsebenzi Wokuhlola: Ngaphambi kokusetshenziswa okugcwele, hlola ukukhishwa kwe-shunt ngaphansi kwezimo ezilawulwayo ukuze uqinisekise ukusebenza okufanele.

★ Ithiphu Yokulungisa: Njalo hlola izintambo ezixhunywe kuzo ukuze uthole izimpawu zokuguga noma zokonakala. Gcina indawo ezungeze ukukhishwa kwe-shunt ihlanzekile futhi ingenalo uthuli ukuze uqinisekise ukusebenza okuthembekile.

I-Wiring Diagram Uhlolojikelele

Umdwebo wezintambo we-CDADA MCCB Shunt Release uqondile:

● SB2: Ivula inkinobho yokucindezela (ihlinzekwe ngumsebenzisi).

● I-P3, i-P4: Izinombolo zetheminali zokuxhuma isignali yakho yokulawula.

● Nathi: Lawula ukunikezwa kwamandla.

● QF: Oxhumana naye osizayo.

Imigqa ephukile kuphela kumdwebo odinga uxhumano lomsebenzisi-zonke ezinye izintambo ezidingekayo zifika zixhunywe ngaphambili kusuka efekthri, okwenza ukufaka kusheshe futhi kube lula.

Inothi Lokufaka: Njalo hlola kabili izintambo zakho ngaphambi kokufaka amandla ukuze ugweme noma yiziphi izingozi ezingaba khona.

imibuzo ejwayelekile ukubuzwa

Q1: Kusho ukuthini "ukukhululwa kwe-shunt"?

I-A1: Ukukhishwa kwe-shunt kuyinto esetshenziselwa ukuvula ukude i-circuit breaker esimweni esiphuthumayo noma izidingo ezithile zokusebenza. Inikeza indlela yokunqamula ngokushesha amandla ngaphandle kokufinyelela ngokomzimba ku-breaker ngokwayo.


Q2: Ngingakwazi ukusebenzisa lokhu kukhishwa kwe-shunt nganoma iyiphi i-MCCB?

I-A2: Cha, kufanele ihambisane nemodeli ye-MCCB kanye ne-voltage yayo yokulawula. Ukukhishwa kwethu kwe-shunt kuklanyelwe ukusebenza ngaphandle komthungo nama-CDADA MCCBs kodwa kungase futhi kuhambisane nezinye izinhlobo—uma ungaqiniseki, thintana nethimba lethu labasekeli bezobuchwepheshe.


Q3: Ingabe ukukhishwa kwe-shunt kulungele kokubili izinhlelo zokusebenza ze-AC ne-DC?

A3: Yebo, ukukhishwa kwethu kwe-shunt kusekela kokubili izinhlelo zokusebenza ze-AC (220V, 380V) kanye ne-DC (110V, 220V), ihlinzeka ngokuguquguquka ezindaweni ezihlukahlukene.


Q4: Kungani ukhetha ukukhululwa kwe-CDADA shunt ngaphezu kwabanye?

A4: Kwa-CDADA, sibeka phambili:

● Ukuqinisekisa Ikhwalithi: Ukuhlola okuqinile kuqinisekisa ukuthi iyunithi ngayinye ihlangabezana namazinga aphezulu.

● Ukufaka kalula: Amayunithi anezintambo zangaphambili zonga isikhathi futhi anciphisa amaphutha.

● Usekelo Lwekhasimende: Usizo oluqondile oluvela ethimbeni lethu elinolwazi.

● Ukusebenza Kwezindleko: Amanani ancintisanayo ngaphandle kokufaka engozini ikhwalithi.

Inothi lokugcina elivela ku-CDADA

Ukukhetha ukukhululwa kwe-shunt okulungile kungathuthukisa kakhulu ukuphepha nokusebenza kwamasistimu akho kagesi. Nge-CDADA, awugcini nje ngokuthola ingxenye—uzuza uzakwethu ozinikele ekwenzeni okuhle kuyo yonke imininingwane. Masikusize uzuze ukuthula kwengqondo ngezixazululo zethu ezithembekile nezisebenziseka kalula.

Hot Tags: Ukukhishwa kwe-MCCB Shunt, eShayina, Umkhiqizi, Umphakeli, Imboni
Thumela Uphenyo
Ulwazi Lokuxhumana

Vula Isixazululo Sakho Sikagesi Esingokwezifiso Emahoreni angama-24!

Kungani Ubuza Nomkhiqizi WaseShayina Osezingeni Eliphezulu?

✅ Amanani Aqondile Embonini

Nciphisa izindleko ze-middleman! Njengefekthri enesitifiketi se-ISO 9001 e-China, siletha ama-MCCB e-premium, ama-MCB, nama-solar DC breaker ngamanani ancintisanayo—okusekelwe yi-CE, KEMA, kanye nezitifiketi ze-ASTA.

✅ Iminyaka engu-40+ Yobuchwepheshe be-OEM/ODM

Shintsha ama-casings, amalebula, noma imininingwane yobuchwepheshe kalula. Ithimba lethu le-R&D (amalungelo obunikazi angama-60+) liphatha:

Izilinganiso zangokwezifiso ze-voltage/zamanje

Ukupakisha okunophawu

I-prototyping esheshayo (amasampula ezinsukwini eziyi-7)

✅ 3 Million+ Amayunithi Amandla Wonyaka

Alikho i-oda elikhulu kakhulu noma eliphuthumayo! Iziqinisekiso zethu zezitshalo ezingama-52,400㎡:

◆ Izikhathi zokuhola zezinsuku eziyi-15 zama-oda amaningi

◆ Ama-MOQ aguquguqukayo

◆ Ukuhlolwa okuqinile kwe-ASTM/UL

✅ Ukuthobelana Kwembulunga yonke, I-Zero Hassle

Sixazulula izithiyo zokuthumela ngaphandle zamazwe angama-45+:

Imibhalo ye-RoHS/REACH

Izitifiketi eziqondene nesifunda

Ama-Solar DC amaphrojekthi aluhlaza we-EU

X
Sisebenzisa amakhukhi ukukunikeza umuzwa ongcono wokuphequlula, ukuhlaziya ithrafikhi yesayithi nokwenza okuqukethwe kube ngokwakho. Ngokusebenzisa le sayithi, uyavumelana nokusebenzisa kwethu amakhukhi.Inqubomgomo yobumfihlo
YenqabaYamukela