Imikhiqizo
3 Phase Air Circuit Breaker
  • 3 Phase Air Circuit Breaker3 Phase Air Circuit Breaker

3 Phase Air Circuit Breaker

Model:DAA
I-CDADA ingumkhiqizi we-3 phase air circuit breaker, lo mkhiqizo ulungele ukutholakala ngobuningi, isixazululo esiguquguqukayo esakhelwe amanethiwekhi okusabalalisa amandla ezimboni ngesilinganiso esingu-400A-6300A. Ifaka ukuvikelwa okuhlakaniphile nokuhamba okuqondile okukhethayo, okuhambisana ne-GB14048.2 ne-IEC60947-2. Yindlela yokuya ku-3P ACB yama-OEM nabasabalalisi abadinga i-switchgear eqinile, ethembekile ephansi yamaphrojekthi omhlaba.

Le CDADA 3 phase circuit breaker yakhelwe amanethiwekhi e-AC 50Hz 690V anobubanzi bamanje obungu-400A-6300A bokusetshenziswa kwezimboni okuhlukahlukene. Njengefekthri ephrofeshinali, umkhiqizo wethu uletha isivikelo esigcwele ngokumelene nokugcwala ngokweqile, isifunda esifushane, i-undervoltage kanye namaphutha aphansi esigaba esisodwa. Le 3P ACB ethuthukisiwe ifaka ukuvikela okuhlakaniphile nokuxhumana okuvulekile Nezilawuli-kude ezine, okuqinisekisa ukusebenza okuthembekile kuzo zonke izidingo zokusabalalisa amandla.


Ipharamitha yomkhiqizo (Ukucaciswa)

Uchungechunge lwamamodeli: I-DAA
Uzimele Ukalwe Okwamanje (I-Inm): 400/500/630/800/1000/1600/2000/ 3200/ 4000/5000/ 6300A
Kukalwe Okwamanje (Kuphakathi): 400A ~ 6300A
Izigxobo: I-3P ejwayelekile (4P uyazikhethela)
I-Voltage elinganiselwe (Ue): 400V / 690V
I-Impulse Withstand Voltage: 8000V @ 2000m altitude (≤12000V max)
I-Icu (400V/690V): 80kA - 120kA / 50kA - 80kA
n×Icu (400V/690V): 176kA/0.2 - 264kA/0.2 / 105kA/0.25 - 187kA/0.2
I-Ics (400V/690V): 50kA - 80kA / 40kA - 70kA
I-Icw (1s): 50kA - 100kA(MCR) @ 400V; 40kA - 75kA(MCR) @ 690V
Ukuthobela Amazinga: I-GB14048.2, IEC60947-2

3 Phase Air Circuit Breaker

Isici somkhiqizo kanye nesicelo

I-CDADA 3 phase air circuit breaker yakhelwe izinhlelo zokusebenza ezihlukene ezihlanganisa izimboni zamandla, iziteshi ezincane, kanye nezindawo zokukhiqiza ezinkulu. Itholakala kuzo zombili izinhlobo ezilungisiwe kanye nekhabethe, isekela ukulungiswa kokushintshashintsha okushisayo, ukunciphisa isikhathi sokuphumula. Ifakwe izilawuli ezihlakaniphile, abasebenzisi bangenza ngokwezifiso izilungiselelo zokuvikela ngokuya ngezidingo ezithile.

Izici Eziyinhloko:

● Izinketho Zokulawula Ezihlakaniphile: bse5 (H uhlobo), bse4 (uhlobo lwe-M), bse3 (uhlobo L)

● Imisebenzi Yokuvikela: Ukulayisha ngokweqile umkhawulo wesikhathi esiphambene wokulibaziseka okude, ukulibaziseka okufushane umkhawulo wesikhathi esiphambene, umkhawulo wesikhathi oqondile, umsebenzi osheshayo, ukuvikela okuyisisekelo kwesigaba esisodwa

● Imisebenzi yokubonisa ne-alamu: Isibonisi sesikhathi sangempela samanje nesomthamo wegesi, i-alamu yokulayisha ngokweqile, umsebenzi wokuzihlola

● I-Communication Interface: Vula iphrothokholi esekela “Izilawuli-kude ezine”


Imininingwane Yokukhiqiza

Ikhiqizwe yi-SHANGHAI DADA ELECTRIC CO.,LTD, njalo ngezigaba ezi-3 ze-ACB ibhekana nokuhlolwa okuqinile nezinqubo zokulawula ikhwalithi. 

Izici ezibalulekile zifaka:

● Ikhwalithi Yezinto Ezibalulekile: Izixhumanisi zethusi ezingenawo umoya-mpilo nezimbondelene zengxubevange yesiliva

● Ububanzi bezinga lokushisa: Isebenza ngaphakathi kwamazinga okushisa aphakathi kuka -5°C kuya +40°C, ngezinketho eziphansi (-10°C noma -25°C) nangaphezulu (+40°C) ngokwedlulele lapho iceliwe.

● Ukusebenza kwe-Altitude: Kufika ku-2000m altitude, nokulungiswa okutholakalayo kokuphakama okuphezulu

● Ukumelana Nemvelo: Izinga lokuvikela le-IP30, elifanele izindawo ezisezingeni lokungcola III

Amathiphu esondlo:

● Ukuhlolwa okuvamile kwezindawo zokuthintana nama-arc chute

● Qinisekisa ukuqondanisa okufanele nokukhweza okuvikelekile

● Ukuhlolwa ngezikhathi ezithile kwemisebenzi yesilawuli ehlakaniphile


FAQ

Q1: Yiziphi izindlela ezihlukene zokufaka ezitholakalayo ze-CDADA 3 phase ACB?

I-A1: Ama-CDADA 3 Phase Air Circuit Breaker ayatholakala kuzo zombili izinhlobo ezingaguquki kanye nezakhakhabethe, okuvumela ukuguquguquka okusekelwe ezidingweni zakho zokufaka.


I-Q2: Ingabe lesi siphukuphuku singasetshenziswa ekucushweni kwezigxobo ezintathu kanye nezigxobo ezine?

A2: Yebo, i-CDADA 3 phase ACB iyatholakala kukho kokubili ukulungiselelwa kwe-3P (okujwayelekile) kanye ne-4P, kuye ngezidingo zakho zohlelo lokusebenza.


I-Q3: Ingabe i-ACB yesigaba se-3 iza nesilawuli esihlakaniphile?

I-A3: Nakuba imodeli eyisisekelo ingasebenza njengesihlukanisi ngaphandle kwesilawuli esihlakaniphile, izilawuli ezihlakaniphile ozikhethela zona (bse5, bse4, bse3) ziyatholakala ukuze kuvikelwe okuthuthukisiwe nokuqapha okukude.


I-Q4: I-impulse ukumelana ne-voltage ihluka kanjani ngokuphakama?

I-A4: I-voltage ye-impulse ukumelana yi-8000V ekuphakameni kwamamitha angu-2000 futhi akufanele idlule ku-12000V ezindaweni eziphakeme.


Q5: Ingabe i-CDADA 3 phase ACB iyahambisana namazinga omhlaba?

A5: Yebo, i-CDADA 3 yesigaba se-ACB ithobelana nawo womabili amazinga kazwelonke (GB14048.2) nawamazwe ngamazwe (IEC60947-2), iqinisekisa ukuthi iyasebenza emhlabeni wonke.

Hot Tags: 3 Phase Air Circuit Breaker, China, Umkhiqizi, Umhlinzeki, Ifektri
Thumela Uphenyo
Ulwazi Lokuxhumana

Vula Isixazululo Sakho Sikagesi Esingokwezifiso Emahoreni angama-24!

Kungani Ubuza Nomkhiqizi WaseShayina Osezingeni Eliphezulu?

✅ Amanani Aqondile Embonini

Nciphisa izindleko ze-middleman! Njengefekthri enesitifiketi se-ISO 9001 e-China, siletha ama-MCCB e-premium, ama-MCB, nama-solar DC breaker ngamanani ancintisanayo—okusekelwe yi-CE, KEMA, kanye nezitifiketi ze-ASTA.

✅ Iminyaka engu-40+ Yobuchwepheshe be-OEM/ODM

Shintsha ama-casings, amalebula, noma imininingwane yobuchwepheshe kalula. Ithimba lethu le-R&D (amalungelo obunikazi angama-60+) liphatha:

Izilinganiso zangokwezifiso ze-voltage/zamanje

Ukupakisha okunophawu

I-prototyping esheshayo (amasampula ezinsukwini eziyi-7)

✅ 3 Million+ Amayunithi Amandla Wonyaka

Alikho i-oda elikhulu kakhulu noma eliphuthumayo! Iziqinisekiso zethu zezitshalo ezingama-52,400㎡:

◆ Izikhathi zokuhola zezinsuku eziyi-15 zama-oda amaningi

◆ Ama-MOQ aguquguqukayo

◆ Ukuhlolwa okuqinile kwe-ASTM/UL

✅ Ukuthobelana Kwembulunga yonke, I-Zero Hassle

Sixazulula izithiyo zokuthumela ngaphandle zamazwe angama-45+:

Imibhalo ye-RoHS/REACH

Izitifiketi eziqondene nesifunda

Ama-Solar DC amaphrojekthi aluhlaza we-EU

X
Sisebenzisa amakhukhi ukukunikeza umuzwa ongcono wokuphequlula, ukuhlaziya ithrafikhi yesayithi nokwenza okuqukethwe kube ngokwakho. Ngokusebenzisa le sayithi, uyavumelana nokusebenzisa kwethu amakhukhi.Inqubomgomo yobumfihlo
YenqabaYamukela