Izindaba

I-Dada Electric Iqondanisa I-DAM1 MCCB Platform yabakhi Bephaneli Yokuthekelisa

2026-11-06 0 Ngishiyele umlayezo

Inkundla eyodwa ye-thermal-magnetic kusuka ku-12.5 A kuya ku-1600 A, isethi egcwele yezinsiza ezifakekayo, kanye nemibhalo ye-CB ne-CE - eyakhelwe izitolo zamaphaneli ezithumela amakhabethe, hhayi amakhathalogi.

DAM1N-125, 3-pole: 125 A, 400/415 V AC, Icu 25 kA at 400 V, Ics 50% of Icu, Uimp 8 kV, utilisation category A. CE and CB marked on the device.

I-DAM1N-125, 3-pole: 125 A, 400/415 V AC, Icu 25 kA ku-400 V, Ics 50% ye-Icu, Uimp 8 kV, isigaba sokusebenzisa A. CE kanye ne-CB emakwe kudivayisi.

I-SHANGHAI - I-Shanghai Dada Electric ihlanganise okunikezwayo kwayo kwe-case breaker breaker (MCCB) elungiselelwe abakhi bephaneli abagxile ekuthumeleni ngaphandle endaweni eyodwa: uchungechunge lwe-DAM1. Ububanzi buhlanganisa i-12.5 A kuya ku-1600 A kuzinguqulo ze-1P, 2P, 3P kanye ne-4P, kuma-voltage okusebenza alinganiselwe afika ku-400/415 V AC, futhi yakhelwe futhi yahlolwa ku-EN 60947-1 kanye ne-EN 60947-2. Uhlaka lwe-125 A, i-DAM1N-125, imakwe kumthamo wokuphuka ongu-25 kA ku-400 V ne-Ics engamaphesenti angu-50.

Lesi sinyathelo siphendula inkinga ekhona ebhizinisini lephaneli yokuthekelisa. Abakhi beKhabhinethi abavamile ukuthenga ibhulabhula elilodwa - bathenga ibhili lezinto okufanele zidlulisele ukubuyekezwa kobuchwepheshe bekhasimende, kucace amasiko, futhi kuphindekeke uma kulandelwa i-oda elilandelayo. Lonke uchungechunge olwengeziwe kuleyo BOM yengeza idatha yedatha, ingxenye eyisipele kanye neseshini yokuqeqesha.

Kungani lokhu kubalulekile manje

Izikhathi zokuhola ze-high-voltage switchgear kanye nama-transformer sezifinyelele eminyakeni emibili kuya kwemithathu eYurophu naseNyakatho Melika, ngokusho kwedatha yemboni ecashunwe ngabakwaReuters. Abakhi bephaneli ababanjwe kulowo mugqa bafuna abahlinzeki be-low-voltage abangafaneleka kanye bese bethembela kubo ukuze baphinde baphinde.

Ngasikhathi sinye, ukuthunyelwa kukagesi okune-voltage ephansi eChina kufinyelele ku-USD 22.32 billion ngo-2025, kwenyuke ngamaphesenti angama-7.2 unyaka nonyaka, ngekota yokuqala ka-2025 ukuthunyelwa kwamanye amazwe kwe-USD 5.6 billion, kukhuphuke ngamaphesenti ayi-13.6, ngokwezibalo zamasiko. Isidingo akusona isithiyo. Ukufaneleka kanye nokuvumelana kokulethwa kukhona.

"Umbuzo ovela kumakhi wephaneli awulokothi uthi 'iyiphi i-breaker yakho eshibhe kakhulu'. Uwukuthi 'ingabe isiqukathi esilandelayo sizoba i-breaker efanayo'."

Inkundla eyodwa, 12.5 A kuya ku-1600 A

I-DAM1 isebenzisa ukuvikelwa kwe-thermal-magnetic: i-elementi ye-bimetal yokulayisha ngokweqile, kanye nohambo lukazibuthe lwesekhethi emfishane. Inkundla yabelana ngesistimu yesisetshenziswa esisodwa kanye nengqondo yokufaka eyodwa kubo bonke osayizi bozimele, ukuze umakhi wephaneli angakwazi ukuma emndenini owodwa esikhundleni sokuhlanganisa abane. Izinguqulo ezishisayo-kazibuthe neziguquguqukayo zombili ziyatholakala - uhlobo olungaguquki, i-thermal-magnetic eguquguqukayo, kanye nohlaka oluguquguqukayo lwe-125 A.

Izilinganiso njengoba zimakwe kudivayisi

Ipharamitha I-DAM1N-125, i-3-pole
Ikalwe okwamanje, In 125 A
I-voltage yokusebenza elinganiselwe, Ue 400 / 415 V AC, 50 Hz
I-voltage ye-insulation elinganiselwe, i-Ui 690v
I-impulse elinganiselwe imelana ne-voltage, i-Uimp 8 kv
Ilinganiswe umthamo wokuphulwa, Icu 40 kA ku-230 V · 25 kA ku-400 V · 4 kA ku-690 V
Umthamo wokuphulwa kwesevisi elinganiselwe, Ics 50% we-Icu (12.5 kA ku-400 V)
Isigaba sokusetshenziswa A
Okujwayelekile EN 60947-2
Ukumaka CE, CB

I-Platform ububanzi nokubekezela

Uhlaka Izigxobo I-Dielectric ukumelana (V) Impilo yemishini Impilo kagesi
I-DAM1-160 (1P) 1P 2,500 17,000 3,000
I-DAM1-200 2P 2,500 12,500 2,500
I-DAM1-125 3P / 4P 2,500 7,000 1,000
I-DAM1-160 3P / 4P 3,000 7,000 1,000
I-DAM1-250 3P / 4P 3,000 7,000 1,000
I-DAM1-400 / 630 3P / 4P 3,000 4,000 1,000

1. Izinsiza zizifaka ngokuzimela

Ukuthinta i-alamu, ukuthintana okusizayo, ukukhishwa kwe-undervoltage, ukukhishwa kwe-shunt, indlela yokusebenza yesibambo, i-opharetha yemoto, idivayisi ye-plug-in kanye nedivayisi yokukhipha konke kwengezwa ku-base breaker efanayo - bona umsizi wokuxhumana kanye nobubanzi bokukhishwa kwe-shunt. Umzimba owodwa, ukulungiselelwa okuningana: ukukhubeka ukude, ukuvikelwa kokuphelelwa amandla kagesi, impendulo yesimo nokulungiswa okukhiphekayo ngaphandle kokuvula ingxenye yenombolo entsha kuyo yonke inhlanganisela.

Okuzuzwa umakhi wephaneli empeleni

1. Izinsiza zizifaka ngokuzimela

Ukuthinta i-alamu, ukuthintana okusizayo, ukukhishwa kwe-undervoltage, ukukhishwa kwe-shunt, indlela yokusebenza yesibambo, i-opharetha yemoto, idivayisi ye-plug-in kanye nedivayisi yokukhipha konke kwengezwa ku-base breaker efanayo - bona umsizi wokuxhumana kanye nobubanzi bokukhishwa kwe-shunt. Umzimba owodwa, ukulungiselelwa okuningana: ukukhubeka ukude, ukuvikelwa kokuphelelwa amandla kagesi, impendulo yesimo nokulungiswa okukhiphekayo ngaphandle kokuvula ingxenye yenombolo entsha kuyo yonke inhlanganisela.

2. Imvilophu encane, ukubuyisela kalula

Uma siqhathanisa, ubukhulu nesisindo se-DAM1 kuphansi ngamaphesenti ayi-10 kuye kwangama-20 kunamamodeli asekhaya aqhathaniswayo. Izinqamuli ezincane zisho indawo ebiyelwe encane, ithusi elincane kanye nempahla ephansi. Amafreyimu angu-125 A kanye no-160 A agibeleka ngokuqondile kuloliwe we-DIN ngesiqeshana esizinikele - awusizo kumabhodi okusabalalisa ahlangene kanye nokufaka esikhundleni sokuphuka kwefa emakhabetheni akhona. Kumaphrojekthi abekwe ngojantshi azinikele, uhla lwe-DIN ujantshi we-MCCB luhlanganisa umndeni wozimele ohlukile.

3. Izincwadi ezisinda emasikweni nasekuthunyweni

I-Dada Electric isebenzisa isistimu yekhwalithi ye-ISO 9001 futhi iphethe isitifiketi se-CE, CB, KEMA kanye ne-ASTA kububanzi bayo bokuphula. Ukupakisha okuthekelisa, idatha ye-nameplate kanye nemibhalo yesimemezelo kulungiswa nge-oda ngalinye. Isitifiketi asisona isihlukanisi kumininingwane yedatha; kuyisizathu sokuthi isitsha sivunyelwe ukuhamba. Iphrofayili yenkampani nezitifiketi.

Izilungiselelo ezijwayelekile

Isicelo Uhlaka olunconyiwe Izesekeli ezibalulekile
Amabhodi okusabalalisa aphansi nawokugcina I-DAM1-125 / 160, 3P noma i-4P Oxhumana naye we-alamu + osizayo
Amasekhethi okuphakelayo kumaphaneli okusabalalisa amandla I-DAM1-250 / 400 Shunt ukukhululwa + oxhumana naye osizayo
Iswishi enkulu engenayo ifika ku-630 A I-DAM1-630 I-motor operator + ukukhishwa kwe-undervoltage
Umtholi ophezulu wamanje noma ibhasi I-DAM1-800 / 1600 Idivayisi yokudonsa + i-motor operator
Amagatsha adinga ukuvikelwa kokuvuza komhlaba Idatha ye-DAM1L Inkundla efanayo, izinhlobo ezimbalwa ezixubile

Mayelana ne-Shanghai Dada Electric

Inkampani engu-Inkampani engu-Shanghai Dada Electric Co., Ltd.idizayina, ikhiqize futhi ithumele ngaphandle ukuvikelwa kwesekethe ye-voltage ephansi evela e-Shanghai, ngaphakathi kweqembu lokukhiqiza elaqala e-Liushi, e-Yueqing ngo-1986; imboni yase-Shanghai yasungulwa ngo-2004. Le nkampani inelayisense yayo yokuthumela ngaphandle futhi inikeza ama-circuit breaker abunjiwe, ama-circuit breaker, amadivaysi amanje asele kanye nama-air circuit breaker kubakhi bamaphaneli, abasabalalisi kanye namakhasimende e-OEM emhlabeni jikelele. Izinhlelo ze-OEM ne-ODM zihlanganisa ukupakishwa kwelebula yangasese kanye nedatha ye-nameplate eqondene nemakethe.

Cela imininingwane ye-DAM1 kanye nephekhi yesitifiketi

Sitshele uhla lwakho lwamanje oluhlosile, ukumiswa kwesigxobo kanye nemakethe yendawo. Sizothumela idatha yozimele efanayo, izinkomba zesitifiketi kanye neshejuli yesampula.

www.dadabreaker.com/message.html · charlotte@dadabreaker.com

Izimpendulo ezisheshayo

I-DAM1 MCCB ihlanganisa luphi uhla lwamanje?

12.5 A ukuya ku-1600 A, kuwo wonke amafreyimu ukusuka ku-DAM1-125 kuya ku-DAM1-1600, kuzinguqulo ze-1P, 2P, 3P kanye ne-4P, kuma-voltage okusebenza alinganiselwe afika ku-400/415 V AC.

Ingakanani amandla okuphuka kwe-DAM1N-125?

I-Icu 25 kA ku-400 V, 40 kA ku-230 V kanye no-4 kA ku-690 V, ne-Ics kumaphesenti angu-50 e-Icu kanye ne-impulse elinganiselwe imelana no-voltage ongu-8 kV.

Ingabe uyawasekela ama-oda we-OEM ne-ODM?

Yebo. I-Dada Electric inikeze ngezinhlelo ze-OEM ne-ODM kumakhasimende athumela ngaphandle, okuhlanganisa ukupakishwa kwelebula yangasese kanye nedatha ye-nameplate eqondene nemakethe.

Izindaba Ezihlobene
Ngishiyele umlayezo
X
Sisebenzisa amakhukhi ukukunikeza umuzwa ongcono wokuphequlula, ukuhlaziya ithrafikhi yesayithi nokwenza okuqukethwe kube ngokwakho. Ngokusebenzisa le sayithi, uyavumelana nokusebenzisa kwethu amakhukhi. Inqubomgomo yobumfihlo
YenqabaYamukela